UMIN-ICDS Clinical Trial

Unique ID issued by UMIN UMIN000063706
Receipt number R000072896
Scientific Title Automated Calculation of Size-Specific Dose Estimates Based on CT Images
Date of disclosure of the study information 2026/11/20
Last modified on 2026/11/20 14:18:55

* This page includes information on clinical trials registered in UMIN clinical trial registed system.
* We don't aim to advertise certain products or treatments


Basic information

Public title

A Study on the Automated Estimation of Patient Size-Specific Radiation Dose Based on CT Images

Acronym

Study of Radiation Dose Estimation in CT

Scientific Title

Automated Calculation of Size-Specific Dose Estimates Based on CT Images

Scientific Title:Acronym

Automated Calculation of SSDE Based on CT Images

Region

Japan


Condition

Condition

Patients Undergoing CT Examinations

Classification by specialty

Pediatrics Radiology Adult
Child

Classification by malignancy

Others

Genomic information

NO


Objectives

Narrative objectives1

The volume CT dose index (CTDIvol) is widely used as a dose index for CT examinations. The dose represented by CTDIvol is the integrated dose measured within a standardized acrylic phantom and does not take into account patient size or X-ray attenuation. Therefore, discrepancies may arise between CTDIvol and the actual radiation dose absorbed by patients. The American Association of Physicists in Medicine (AAPM) proposed the size-specific dose estimate (SSDE), which estimates the absorbed dose to patients by applying conversion factors according to patient size, and this concept has also been incorporated into its guidelines. SSDE is derived by determining a size conversion factor based on the effective diameter (ED) or water-equivalent diameter (Dw) of the subject and applying it to CTDIvol to estimate the absorbed dose. This index reflects X-ray attenuation corresponding to patient size and enables a more accurate estimation of the actual absorbed dose. However, calculating SSDE is time-consuming for routine clinical use, and manual calculation is cumbersome except on systems equipped with dedicated software. The purpose of this study is to develop a program that automatically calculates SSDE from CT images and to validate its performance using clinical data.

Basic objectives2

Efficacy

Basic objectives -Others


Trial characteristics_1


Trial characteristics_2


Developmental phase



Assessment

Primary outcomes

To evaluate the agreement and differences between Size-Specific Dose Estimates (SSDEs) automatically calculated from CT images using a custom-developed program and those provided by the CT scanner.

Key secondary outcomes

To evaluate the agreement and differences between values of effective diameter (ED) and water-equivalent diameter (Dw) calculated using a custom-developed program and those provided by the CT scanner during the SSDE calculation process.


Base

Study type

Observational


Study design

Basic design


Randomization


Randomization unit


Blinding


Control


Stratification


Dynamic allocation


Institution consideration


Blocking


Concealment



Intervention

No. of arms


Purpose of intervention


Type of intervention


Interventions/Control_1


Interventions/Control_2


Interventions/Control_3


Interventions/Control_4


Interventions/Control_5


Interventions/Control_6


Interventions/Control_7


Interventions/Control_8


Interventions/Control_9


Interventions/Control_10



Eligibility

Age-lower limit


Not applicable

Age-upper limit


Not applicable

Gender

Male and Female

Key inclusion criteria

Patients who underwent CT examinations for clinical purposes at Ibaraki Prefectural University of Health Sciences Hospital and did not meet any of the exclusion criteria.A minimum of 30 cases of image data will be collected for each of the following four categories: adult torso, adult head, pediatric torso, and pediatric head. The data will be obtained from CT examinations performed using the SOMATOM go.Top scanner at Ibaraki Prefectural University of Health Sciences Hospital between March 2024 and October 2026.

Key exclusion criteria

Cases in which image processing is difficult due to poor image quality caused by patient motion, metal artifacts, reconstruction artifacts, or other factors.

Target sample size

120


Research contact person

Name of lead principal investigator

1st name Atsushi
Middle name
Last name Urikura

Organization

Ibaraki Prefectural University of Health Sciences

Division name

Department of Radiological Sciences

Zip code

300-0331

Address

Room 304, Ibaraki Prefectural University of Health Sciences Faculty Housing, 4733 Ami, Ami-machi, Inashiki-gun, Ibaraki, Japan

TEL

090-3630-4759

Email

urikuraat@ipu.ac.jp


Public contact

Name of contact person

1st name Atsushi
Middle name
Last name Urikura

Organization

Ibaraki Prefectural University of Health Sciences

Division name

Department of Radiological Sciences

Zip code

300-0331

Address

Room 304, University Faculty Housing, 4733 Ami, Ami-machi, Inashiki-gun, Ibaraki, Japan

TEL

090-3630-4759

Homepage URL


Email

urikuraat@ipu.ac.jp


Sponsor or person

Institute

Ibaraki Prefectural University of Health Sciences

Institute

Department

Personal name

Atsushi Urikura


Funding Source

Organization

Ibaraki Prefectural University of Health Sciences

Organization

Division

Category of Funding Organization

Local Government

Nationality of Funding Organization



Other related organizations

Co-sponsor


Name of secondary funder(s)



IRB Contact (For public release)

Organization

Research Ethics Committee of Ibaraki Prefectural University of Health Sciences

Address

4669-2 Ami, Ami-machi, Inashiki-gun, Ibaraki, Japan

Tel

029-888-4000

Email

kyoumu@ipu.ac.jp


Secondary IDs

Secondary IDs

NO

Study ID_1


Org. issuing International ID_1


Study ID_2


Org. issuing International ID_2


IND to MHLW



Institutions

Institutions



Other administrative information

Date of disclosure of the study information

2026 Year 11 Month 20 Day


Related information

URL releasing protocol


Publication of results

Unpublished


Result

URL related to results and publications


Number of participants that the trial has enrolled


Results


Results date posted


Results Delayed


Results Delay Reason


Date of the first journal publication of results


Baseline Characteristics


Participant flow


Adverse events


Outcome measures


Plan to share IPD


IPD sharing Plan description



Progress

Recruitment status

Preinitiation

Date of protocol fixation

2026 Year 10 Month 07 Day

Date of IRB


Anticipated trial start date

2026 Year 12 Month 01 Day

Last follow-up date

2027 Year 02 Month 28 Day

Date of closure to data entry


Date trial data considered complete


Date analysis concluded



Other

Other related information

This study is a single-center, retrospective observational study involving previously acquired head and torso CT images obtained during routine clinical practice. The study subjects will include both adults and children, and CT images and information regarding scan parameters will be collected. A custom-developed program will be applied to the acquired CT images to automatically calculate the effective diameter (ED), water-equivalent diameter (Dw), and size-specific dose estimate (SSDE). The values calculated by the custom-developed program will be compared with those output by the CT scanner to evaluate their agreement and differences. Furthermore, differences in the calculated results according to the scanned anatomical region (head or torso) and age group (adults or children) will also be investigated.


Management information

Registered date

2026 Year 11 Month 20 Day

Last modified on

2026 Year 11 Month 20 Day



Link to view the page

Value
https://center6.umin.ac.jp/cgi-open-bin/ctr_e/ctr_view.cgi?recptno=R000072896