| Unique ID issued by UMIN | UMIN000063706 |
|---|---|
| Receipt number | R000072896 |
| Scientific Title | Automated Calculation of Size-Specific Dose Estimates Based on CT Images |
| Date of disclosure of the study information | 2026/11/20 |
| Last modified on | 2026/11/20 14:18:55 |
A Study on the Automated Estimation of Patient Size-Specific Radiation Dose Based on CT Images
Study of Radiation Dose Estimation in CT
Automated Calculation of Size-Specific Dose Estimates Based on CT Images
Automated Calculation of SSDE Based on CT Images
| Japan |
Patients Undergoing CT Examinations
| Pediatrics | Radiology | Adult |
| Child |
Others
NO
The volume CT dose index (CTDIvol) is widely used as a dose index for CT examinations. The dose represented by CTDIvol is the integrated dose measured within a standardized acrylic phantom and does not take into account patient size or X-ray attenuation. Therefore, discrepancies may arise between CTDIvol and the actual radiation dose absorbed by patients. The American Association of Physicists in Medicine (AAPM) proposed the size-specific dose estimate (SSDE), which estimates the absorbed dose to patients by applying conversion factors according to patient size, and this concept has also been incorporated into its guidelines. SSDE is derived by determining a size conversion factor based on the effective diameter (ED) or water-equivalent diameter (Dw) of the subject and applying it to CTDIvol to estimate the absorbed dose. This index reflects X-ray attenuation corresponding to patient size and enables a more accurate estimation of the actual absorbed dose. However, calculating SSDE is time-consuming for routine clinical use, and manual calculation is cumbersome except on systems equipped with dedicated software. The purpose of this study is to develop a program that automatically calculates SSDE from CT images and to validate its performance using clinical data.
Efficacy
To evaluate the agreement and differences between Size-Specific Dose Estimates (SSDEs) automatically calculated from CT images using a custom-developed program and those provided by the CT scanner.
To evaluate the agreement and differences between values of effective diameter (ED) and water-equivalent diameter (Dw) calculated using a custom-developed program and those provided by the CT scanner during the SSDE calculation process.
Observational
| Not applicable |
| Not applicable |
Male and Female
Patients who underwent CT examinations for clinical purposes at Ibaraki Prefectural University of Health Sciences Hospital and did not meet any of the exclusion criteria.A minimum of 30 cases of image data will be collected for each of the following four categories: adult torso, adult head, pediatric torso, and pediatric head. The data will be obtained from CT examinations performed using the SOMATOM go.Top scanner at Ibaraki Prefectural University of Health Sciences Hospital between March 2024 and October 2026.
Cases in which image processing is difficult due to poor image quality caused by patient motion, metal artifacts, reconstruction artifacts, or other factors.
120
| 1st name | Atsushi |
| Middle name | |
| Last name | Urikura |
Ibaraki Prefectural University of Health Sciences
Department of Radiological Sciences
300-0331
Room 304, Ibaraki Prefectural University of Health Sciences Faculty Housing, 4733 Ami, Ami-machi, Inashiki-gun, Ibaraki, Japan
090-3630-4759
urikuraat@ipu.ac.jp
| 1st name | Atsushi |
| Middle name | |
| Last name | Urikura |
Ibaraki Prefectural University of Health Sciences
Department of Radiological Sciences
300-0331
Room 304, University Faculty Housing, 4733 Ami, Ami-machi, Inashiki-gun, Ibaraki, Japan
090-3630-4759
urikuraat@ipu.ac.jp
Ibaraki Prefectural University of Health Sciences
Atsushi Urikura
Ibaraki Prefectural University of Health Sciences
Local Government
Research Ethics Committee of Ibaraki Prefectural University of Health Sciences
4669-2 Ami, Ami-machi, Inashiki-gun, Ibaraki, Japan
029-888-4000
kyoumu@ipu.ac.jp
NO
| 2026 | Year | 11 | Month | 20 | Day |
Unpublished
Preinitiation
| 2026 | Year | 10 | Month | 07 | Day |
| 2026 | Year | 12 | Month | 01 | Day |
| 2027 | Year | 02 | Month | 28 | Day |
This study is a single-center, retrospective observational study involving previously acquired head and torso CT images obtained during routine clinical practice. The study subjects will include both adults and children, and CT images and information regarding scan parameters will be collected. A custom-developed program will be applied to the acquired CT images to automatically calculate the effective diameter (ED), water-equivalent diameter (Dw), and size-specific dose estimate (SSDE). The values calculated by the custom-developed program will be compared with those output by the CT scanner to evaluate their agreement and differences. Furthermore, differences in the calculated results according to the scanned anatomical region (head or torso) and age group (adults or children) will also be investigated.
| 2026 | Year | 11 | Month | 20 | Day |
| 2026 | Year | 11 | Month | 20 | Day |
Value
https://center6.umin.ac.jp/cgi-open-bin/ctr_e/ctr_view.cgi?recptno=R000072896