Unique ID issued by UMIN | UMIN000042822 |
---|---|
Receipt number | R000048887 |
Scientific Title | Test of care tasks with humans using a new technology of raising a bedridden person off the bed. |
Date of disclosure of the study information | 2021/01/22 |
Last modified on | 2021/12/14 21:01:45 |
Test of a new lifting technology & device to reduce the load of caregivers working for bedridden persons.
Test of a new lifting technology & device for bed ridden persons.
Test of care tasks with humans using a new technology of raising a bedridden person off the bed.
Test of care tasks using a new technology of raising a person off the bed.
Japan |
Healthy adults
Nursing | Adult |
Others
NO
Feasibility of the new lifting technology & device, which utilizes Japanese futon, to care tasks, its comparative evaluation with the current care technology & device, and the evaluation of the reduction of the physical load on caregiver performers.
Safety,Efficacy
Confirmatory
Pragmatic
Not applicable
Feasible or non-feasible experimental facts of the new lifting technology & device to care tasks for bedridden persons. The results will be obtained at the end of the experiments.
1.Physical load of the caregiver performers using the new technology in comparison with the current one.
2.Comfort or discomfort of care-receiver performers using the new technology in comparison with the current one.
3.Appearance, symmetry and tidiness of the bed after the care tasks using the new technology in comparison with the current one.
4.Required time for care tasks using the new technology in comparison with the current one.
The results will be obtained at the end of the experiments.
Interventional
Single arm
Non-randomized
Open -no one is blinded
Self control
1
Treatment
Device,equipment | Maneuver |
After confirming the applicability of the new technology & the device to care tasks for bedridden persons, 15 pairs of healthy persons participate in the bedsheets change test of an occupied bed. Each of the pair uses the new technology and the current technology, and also alternating the roles of a caregiver and a care-receiver, tries 4 different cases and evaluate them comparatively. The test period is about 3 months.
20 | years-old | <= |
Not applicable |
Male and Female
Those healthy persons who have the skill of the current technology of the care tasks such as bedsheets change.
none
30
1st name | Yuko |
Middle name | |
Last name | Ohno |
Osaka University
Division of Health Science, Graduate School of Medicine
5650871
1-7 Yamadaoka, Suita City, Osaka Pref.
06-6879-2614
ohno@sahs.med.osaka-u.ac.jp
1st name | Tadao |
Middle name | |
Last name | Okada |
Osaka University
Division of Health Science, Graduate School of Medicine
5650871
1-7 Yamadaoka, Suita City, Osaka Pref.
06-6879-2526
25b14804@sahs.med.osaka-u.ac.jp
Division of Health Science, Osaka University Graduate School of Medicine
None
Self funding
1.Prop Co., Ltd.
2.Paramount Bed Co., Ltd.
Ethical Review Board of Osaka University Hospital
2-2 Yamadaoka, Suita City, Osaka Pref.
06-6210-8296
rinri@hp-crc.med.osaka-u.ac.jp
NO
大阪大学大学院医学系研究科保健学専攻(大阪府)
2021 | Year | 01 | Month | 22 | Day |
http://sahswww.med.osaka-u.ac.jp/~fnmet/index.html
Unpublished
30
New tech: making a futon wavy under a person, belts being inserted to wave troughs, tied to a frame, the bed being lowered to lift the person. Feasibility tests: 1. a device set to an occupied bed, 2. sheets change, 3. change upper body clothes & 4. lower ones, 5. bed bath, 6. bedpan insertion, 7. move to a wheelchair, 8. sheet wrinkle removal. All but 3 & 5 were done well. Changing futon sheets with new & current methods by 30 participants: new tech was feasible, giving tidy sheets, but taking longer time.
2021 | Year | 12 | Month | 14 | Day |
Participants: 8 males, 22 females
mean age: 33.7 (SD 10.4) years
mean height: 163.4 (SD 9.2) cm
mean weight: 59.4 (SD 12.1) kg
nurses & midwives (active & former):15
finishers of nursing course: 11
finishers of non-nursing course: 4
Through the teaching staffs whose laboratories were in the same Department where the researchers were based, the participants were recruited, and got 30 applicants. All of them met the inclusion criteria and were enrolled in the test. Though, this was a single arm test, as there existed the orders of the test, i.e. (1) the new technology and device, (2) the current method, or (1) the current method, (2) the new technology, about half of the pair began the test with the new technology and device, and the rest with the current method. The data of 30 participants were used for analyses.
none.
・Feasibility of the new technology & device to care tasks.
・The paired differences of the following variables evaluated by the participants in the test of futon sheets change between using the new technology & device and the current method.
1.Subjective physical load of the simulated caregivers.
2. Subjective comfort or discomfort of the simulated care-receivers.
3. Appearance of the changed sheet.
4. The required time.
none.
Completed
2021 | Year | 01 | Month | 15 | Day |
2021 | Year | 01 | Month | 22 | Day |
2021 | Year | 01 | Month | 22 | Day |
2021 | Year | 03 | Month | 23 | Day |
2021 | Year | 03 | Month | 23 | Day |
2021 | Year | 03 | Month | 31 | Day |
2022 | Year | 09 | Month | 30 | Day |
As for the principles of a wavy futon formation and the insertion of belts between a person and the futon in the Result Column, reference: example 20 and Fig. 11 of WO 2019/027037 A1.
2020 | Year | 12 | Month | 22 | Day |
2021 | Year | 12 | Month | 14 | Day |
Value