Scientific Title | Assessment of lower extremity deep venous thrombosis using a pocket-sized ultrasound device |
Date of disclosure of the study information | 2020/10/06 |
Last modified on | 2020/10/06 07:31:59 |
Assessment of lower extremity deep venous thrombosis using a pocket-sized ultrasound device
Assessment of lower extremity deep venous thrombosis using a pocket-sized ultrasound device
Assessment of lower extremity deep venous thrombosis using a pocket-sized ultrasound device
Assessment of lower extremity deep venous thrombosis using a pocket-sized ultrasound device
Japan |
deep venous thrombosis
Medicine in general | Cardiology | Laboratory medicine |
Others
NO
To assess the performance of a pocket-sized ultrasound device for evaluating lower extremity deep venous thrombosis.
Efficacy
Confirmatory
Not applicable
To assess the diagnostic performance of two point method using a pocket-sized ultrasound device with high-end ultrasound devices as a reference standard for the assessment of proximal deep venous thrombosis of the lower extremity.
1) The concordance of the results between a pocket-sized device and high-end ultrasound devices.
2) The influence of body mass index and the swelling of the lower extremity on the diagnostic accuracy.
Interventional
Single arm
Non-randomized
Open -no one is blinded
Uncontrolled
1
Diagnosis
Device,equipment |
This study is scheduled to be performed during 24 months in 493 patients. Sonographers who have at least one and half years of experience with ultrasound of the lower extremity venous system participate in this study. First, one of the sonographers examines both sides of common femoral veins then popliteal veins using a pocket-sized ultrasound device with B mode (Vscan extended, GE Health Care). If a thrombus is visualized or if the vein is incompressible, the result is defined to be positive. If a thrombus is not visualized and if the femoral and popliteal veins are totally compressible, then the result is defined to be negative. Immediately after completion of the examination using the pocket-sized ultrasound device, another sonographer blinded to the previous results perform a formal systematic examination of lower extremity deep venous system using high-end ultrasound devices with B mode and Doppler mode.
18 | years-old | <= |
Not applicable |
Male and Female
Patients referred to the ultrasound laboratory for the assessment of deep venous thrombosis and who meet one of the followings:
1) swelling of either or both of the lower extremities
2) splinting or casting for the lower extremity
3) preoperative assessment due to treatment of malignant tumors
4) postoperative assessment of the lower extremity
5) suspected or confirmed pulmonary embolism
1) past medical history of deep venous thrombosis
2) the prior confirmation with other imaging modalities
3) the duplicated examination during the study period
493
1st name | Manabu |
Middle name | |
Last name | Izumi |
Saiseikai Utsunomiya Hospital
Department of Clinical Laboratory Medicine
321-0974
911-1 Takebayashi, Utsunomiya, Tochigi, Japan
028-626-5500
manabu_izumi@saimiya.com
1st name | Hideki |
Middle name | |
Last name | Tarakawa |
Saiseikai Utsunomiya Hospital
Department of Clinical Laboratory
321-0974
911-1 Takebayashi, Utsunomiya, Tochigi, Japan
028-626-5500
hideki_tarakawa@saimiya.com
Department of Clinical Laboratory Medicine, Saiseikai Utsunomiya Hospital
None
Self funding
Ethics Committee of Saiseikai Utsunomiya Hospital
911-1 Takebayashi, Utsunomiya, Tochigi, Japan
028-626-5500
rieko_kawauchi@saimiya.com
NO
2020 | Year | 10 | Month | 06 | Day |
Unpublished
Enrolling by invitation
2020 | Year | 09 | Month | 25 | Day |
2020 | Year | 09 | Month | 25 | Day |
2020 | Year | 10 | Month | 06 | Day |
2022 | Year | 09 | Month | 30 | Day |
2020 | Year | 10 | Month | 05 | Day |
2020 | Year | 10 | Month | 06 | Day |
Value
https://center6.umin.ac.jp/cgi-open-bin/ctr_e/ctr_view.cgi?recptno=R000047870