UMIN-CTR Clinical Trial

Recruitment status Completed
Unique ID issued by UMIN UMIN000040154
Receipt No. R000045784
Scientific Title Prospective evaluation of radiofrequency ablation for stent occlusion after bilateral metal stent placement in patients with malignant hilar biliary obstructions
Date of disclosure of the study information 2020/04/14
Last modified on 2022/10/31 (Ver. 2)

* This page includes information on clinical trials registered in UMIN clinical trial registed system.
* We don't aim to advertise certain products or treatments


Basic information
Public title Prospective evaluation of radiofrequency ablation for stent occlusion after bilateral metal stent placement in patients with malignant hilar biliary obstructions
Acronym Prospective evaluation of radiofrequency ablation for stent occlusion after bilateral metal stent placement in patients with malignant hilar biliary obstructions
Scientific Title Prospective evaluation of radiofrequency ablation for stent occlusion after bilateral metal stent placement in patients with malignant hilar biliary obstructions
Scientific Title:Acronym Prospective evaluation of radiofrequency ablation for stent occlusion after bilateral metal stent placement in patients with malignant hilar biliary obstructions
Region
Japan

Condition
Condition unresectable malignant hilar biliary obstruction
Classification by specialty
Hepato-biliary-pancreatic medicine
Classification by malignancy Malignancy
Genomic information NO

Objectives
Narrative objectives1 To evaluate the feasibility and efficacy of RFA for ingrowth after bilateral metal stent placemnt in patients with malignant hilar biliary obstruction
Basic objectives2 Safety,Efficacy
Basic objectives -Others
Trial characteristics_1
Trial characteristics_2
Developmental phase

Assessment
Primary outcomes Technical and functional success
Key secondary outcomes

Base
Study type Observational

Study design
Basic design
Randomization
Randomization unit
Blinding
Control
Stratification
Dynamic allocation
Institution consideration
Blocking
Concealment

Intervention
No. of arms
Purpose of intervention
Type of intervention
Interventions/Control_1
Interventions/Control_2
Interventions/Control_3
Interventions/Control_4
Interventions/Control_5
Interventions/Control_6
Interventions/Control_7
Interventions/Control_8
Interventions/Control_9
Interventions/Control_10

Eligibility
Age-lower limit
20 years-old <=
Age-upper limit

Not applicable
Gender Male and Female
Key inclusion criteria 1) Patients who underwent bilateral metal stent placement for malignant hilar biliary obstruction
2) Patients with stent occlusion because of ingrowth
Key exclusion criteria 1) Patients having difficulty in endoscopy
2) Patients having difficulty in transpapillary approach
3) Patients with surgically altered anatomy
4) Contraindication of RFA
5) Insufficient contact between the electrodes and the tissue
6) Performance status 4
7) Patients without informed consent
8) Inappropriate patients for entry on this study in the judgement of their research investigator
Target sample size 20

Research contact person
Name of lead principal investigator
1st name Tadahisa
Middle name
Last name Inoue
Organization Aichi Medical University
Division name Department of Gastroenterology
Zip code 480-1195
Address 1-1 Yazakokarimata, Nagakute, Aichi, Japan
TEL 0561623311
Email tinoue-tag@umin.ac.jp

Public contact
Name of contact person
1st name Tadahisa
Middle name
Last name Inoue
Organization Aichi Medical University
Division name Department of Gastroenterology
Zip code 480-1195
Address 1-1 Yazakokarimata, Nagakute, Aichi, Japan
TEL 0561623311
Homepage URL
Email tinoue-tag@umin.ac.jp

Sponsor
Institute Aichi Medical University
Institute
Department

Funding Source
Organization Aichi Medical University
Organization
Division
Category of Funding Organization Self funding
Nationality of Funding Organization

Other related organizations
Co-sponsor
Name of secondary funder(s)

IRB Contact (For public release)
Organization Aichi Medical University
Address 1-1 Yazakokarimata, Nagakute, Aichi, Japan
Tel 0561623311
Email tinoue-tag@umin.ac.jp

Secondary IDs
Secondary IDs NO
Study ID_1
Org. issuing International ID_1
Study ID_2
Org. issuing International ID_2
IND to MHLW

Institutions
Institutions

Other administrative information
Date of disclosure of the study information
2020 Year 04 Month 14 Day

Related information
URL releasing protocol
Publication of results Unpublished

Result
URL related to results and publications
Number of participants that the trial has enrolled
Results
Results date posted
Results Delayed
Results Delay Reason
Date of the first journal publication of results
Baseline Characteristics
Participant flow
Adverse events
Outcome measures
Plan to share IPD
IPD sharing Plan description

Progress
Recruitment status Completed
Date of protocol fixation
2020 Year 03 Month 09 Day
Date of IRB
2020 Year 04 Month 10 Day
Anticipated trial start date
2020 Year 04 Month 14 Day
Last follow-up date
2024 Year 03 Month 31 Day
Date of closure to data entry
Date trial data considered complete
Date analysis concluded

Other
Other related information Prospective evaluation of the effeicacy and safety of RFA for stent occlusion after bilateral metal stent placement in patiens with malignant hilar biliary obstructions

Management information
Registered date
2020 Year 04 Month 14 Day
Last modified on
2022 Year 10 Month 31 Day


Link to view the page
URL(English) https://center6.umin.ac.jp/cgi-open-bin/ctr_e/ctr_view.cgi?recptno=R000045784