Unique ID issued by UMIN | UMIN000038635 |
---|---|
Receipt number | R000043897 |
Scientific Title | Randomized comparative study of the appearance of fixation and lip skin troubles due to differences in the shape of the double lumen bronchial tube flange |
Date of disclosure of the study information | 2019/12/20 |
Last modified on | 2025/03/05 11:34:27 |
Randomized comparative study of the appearance of fixation and lip skin troubles due to differences in the shape of the double lumen bronchial tube flange
Randomized comparative study of the appearance of fixation and lip skin troubles due to differences in the shape of the double lumen bronchial tube flange
Randomized comparative study of the appearance of fixation and lip skin troubles due to differences in the shape of the double lumen bronchial tube flange
Randomized comparative study of the appearance of fixation and lip skin troubles due to differences in the shape of the double lumen bronchial tube flange
Japan |
This is mainly intended for patients undergoing thoracic surgery requiring separate lung ventilation, such as lung cancer, pneumothorax, empyema, and mediastinal tumor.
Chest surgery | Anesthesiology |
Malignancy
NO
The shape of the flange (a device for fixing the bronchial tube body to the patient and adjusting the position) attached to the Daiken Medical Co., Ltd. coudec double lumen was changed and sold by the company. Since the tape fixing method has been changed with the flange shape change, the degree of bronchial tube displacement and countermeasures for lip skin problems due to flange fixing will be examined.
Safety
1) New incidence: In each group, the number of new patients is divided by the number of target patients and calculated as a percentage.
Before and after tracheal intubation, observe the teeth and lips and exclude any damage caused by intubation.
2) Site and extent of damage:
The parts are classified into the lips, mouth corners, upper, lower, left and right around the mouth, the cheeks are above and below the nostrils, and the oral cavity is classified into the upper and lower parts of the alveoli and the tongue
The hard palate is excluded because it does not touch the structure.
3) Degree of damage: classified into redness, epidermal detachment, laceration, ulcer and blister
Sensory abnormalities include numbness, pain, and numbness
The range is described in mm (vertical * horizontal), and the depth is not evaluated because a measurable laceration is not expected.
Allows multiple selection of applicable items
1)Degree of bronchial tube displacement: When confirming the position of the tube with a bronchoscope, measure the distance (mm)from the tracheal branch to the tube opening for right lung ventilation to measure the extraction distance of the bronchoscope.
2)Safety assessment,Adverse events
Frequency of tube trouble: The case where the bronchial tube is displaced and the lung on the operation side swells or is inserted deeper and the position of the bronchial tube needs to be corrected during the operation.
Interventional
Parallel
Randomized
Individual
Open -no one is blinded
Active
YES
YES
2
Treatment
Device,equipment |
Existing flange group
New flange group
20 | years-old | <= |
Not applicable |
Male and Female
Intended for patients who meet all of the following criteria:
1)Patients undergoing thoracic surgery requiring separate lung ventilation
2) Patients using Daiken Medical Co., Ltd.'s codec double lumen left (37Fr/35Fr) 1)
3) Patients who are over 20 years old when obtaining consent (regardless of gender)
4) Patients who have received sufficient explanation for participation in this study, and who have obtained written consent from the patient or his / her proxy
1) Daiken Medical Equipment Co., Ltd. codec double lumen is sold only for the left side.
The new flange is not yet compatible with sizes 32Fr and 39Fr.
Patients who violate any of the following will not be included in this study:
1) Patients judged to be inappropriate by the study director
[Rationale for setting]
1) In order to leave room for the research director to decide whether or not to participate in this study, taking into account the general factors other than those mentioned above, taking into account the safety of the subject.
200
1st name | Ryuji |
Middle name | |
Last name | Kajikawa |
IZumi City General Hospital
Department manager of Anesthesiology
594-0073
4-5-1 Wake-cho Izumi Osaka Japan
0725411331
ryuji.kajikawa@tokushukai.jp
1st name | Ryuji |
Middle name | |
Last name | Kajikawa |
IZumi City General Hospital
Department manager of Anesthesiology
594-0073
4-5-1 Wake-cho Izumi Osaka Japan
0725411331
ryuji.kajikawa@tokushukai.jp
IZumi City General Hospital
IZumi City General Hospital
Profit organization
Mirai Iryo Research Center Inc
1-8-7, Koji-machi, Chiyoda-ku, Tokyo 102-0083, Japan
03-3263-4801
mirai-ec1@mirai-iryo.com
NO
2019 | Year | 12 | Month | 20 | Day |
Unpublished
Terminated
2019 | Year | 12 | Month | 04 | Day |
2020 | Year | 01 | Month | 06 | Day |
2020 | Year | 01 | Month | 07 | Day |
2021 | Year | 12 | Month | 20 | Day |
2019 | Year | 11 | Month | 19 | Day |
2025 | Year | 03 | Month | 05 | Day |
Value
https://center6.umin.ac.jp/cgi-open-bin/ctr_e/ctr_view.cgi?recptno=R000043897