Scientific Title | Study of the bevel of tracheal lumen endotracheal opening of double-lumen endobronchial tube |
Date of disclosure of the study information | 2019/11/01 |
Last modified on | 2022/08/01 11:06:38 |
Study of the bevel of tracheal lumen endotracheal opening of double-lumen endobronchial tube
Study of the bevel of tracheal lumen endotracheal opening of double-lumen endobronchial tube
Study of the bevel of tracheal lumen endotracheal opening of double-lumen endobronchial tube
Study of the bevel of tracheal lumen endotracheal opening of double-lumen endobronchial tube
Japan |
differential lung ventilation
Anesthesiology |
Others
NO
Tracheal lumen opening of double-lumen endobronchial tube gets caught on glottis. There is no study about the relationship between the bevel of tracheal lumen opening and glottis. The aim of this study is to reveal the influence to glottis of the bevel of tracheal lumen opening.
Safety
When volunteers insert the double-lumen endobronchial tube into the artificial airway model, the resistance resulted from the caught of the tracheal lumen opening on glottis is measured by digital force gauge attached to the double-lumen endobronchial tube. 2 different type of the bevel of tracheal lumen openings are compared.
When volunteers insert the double-lumen encaught of the tracheal lumen opening on glottis is evaluated dobronchial tube into the artificial airway model, the resistance resulted from the by the volunteers inserting the double-lumen endobronchial tube. 2 different type of the bevel of tracheal lumen openings are compared.
Interventional
Parallel
Non-randomized
Single blind -participants are blinded
Dose comparison
4
Educational,Counseling,Training
Device,equipment |
Volunteer anesthesiologists insert the double-lumen tube into the artificial airway model.
Volunteer anesthesiologists insert the double-lumen tube with other condition into the artificial airway model.
Volunteer anesthesiologists insert the double-lumen tube with other condition into the artificial airway model.
Volunteer anesthesiologists insert the double-lumen tube with other condition into the artificial airway model.
24 | years-old | <= |
80 | years-old | >= |
Male and Female
Volunteers who are certificated anesthesiologists.
Volunteers who are not certificated anesthesiologists.
6
1st name | Shuhei |
Middle name | |
Last name | Matsui |
minaminagano medical center Shinonoi general hospital
division of anesthesia
388-8004
666-1, Shinonoi Ai, Nagano Shi, Nagano Ken, 388-8004, Japan
026-292-2261
matsuimagawa@gmail.com
1st name | Shuhei |
Middle name | |
Last name | Matsui |
minaminagano medical center Shinonoi general hospital
division of anesthesia
388-8004
666-1, Shinonoi Ai, Nagano Shi, Nagano Ken, 388-8004, Japan
026-292-2261
matsuimagawa@gmail.com
minaminagano medical center Shinonoi general hospital
minaminagano medical center Shinonoi general hospital
Self funding
minaminagano medical center Shinonoi general hospital
666-1, Shinonoi Ai, Nagano Shi, Nagano Ken, 388-8004, Japan
026-292-2261
sgh.sino.ane@gmail.com
NO
2019 | Year | 11 | Month | 01 | Day |
Unpublished
6
Power analysis suggested 13 volunteers needed for study with airway model, however we detected significant differences when 6 volunteers were recruited. Effect size and power were unknown in this model. That was the reason why sample size was changed.
2020 | Year | 04 | Month | 09 | Day |
Delay expected |
Clinical demands for COVID-19 disturb progress in this study.
Completed
2019 | Year | 10 | Month | 31 | Day |
2019 | Year | 10 | Month | 05 | Day |
2019 | Year | 11 | Month | 01 | Day |
2024 | Year | 11 | Month | 01 | Day |
2019 | Year | 10 | Month | 09 | Day |
2022 | Year | 08 | Month | 01 | Day |
Value
https://center6.umin.ac.jp/cgi-open-bin/ctr_e/ctr_view.cgi?recptno=R000043578