Unique ID issued by UMIN | UMIN000035993 |
---|---|
Receipt number | R000040999 |
Scientific Title | Influence of capsular tension ring on intracapsular stability and visual function after implantation of multifocal intraocular lens |
Date of disclosure of the study information | 2019/02/24 |
Last modified on | 2023/08/29 10:13:16 |
Influence of capsular tension ring on intracapsular stability and visual function after implantation of multifocal intraocular lens
CTR and multifocal intraocular lens
Influence of capsular tension ring on intracapsular stability and visual function after implantation of multifocal intraocular lens
CTR and multifocal intraocular lens
Japan |
cataract
Ophthalmology |
Others
NO
To investigate the efficacy of capsular tension ring on surgery using multifocal intraocular lens
Efficacy
Stability of intraocular lens 3 months after surgery
Visual function 3 months after surgery
Interventional
Parallel
Randomized
Individual
Open -but assessor(s) are blinded
Placebo
2
Treatment
Device,equipment |
Cataract surgery without capsular tension ring
Cataract surgery with capsular tension ring
20 | years-old | <= |
Not applicable |
Male and Female
Patients with bilateral cataract
Eyes with other ocular diseases
20
1st name | Tetsuro |
Middle name | |
Last name | Oshika |
Faculty of Medicine, University of Tsukuba
Department of Opohthalmology
305-8575
1-1-1 Tennoudai, Tsukuba, Ibaraki
029-853-3148
oshika@eye.ac
1st name | Tetsuro |
Middle name | |
Last name | Oshika |
Faculty of Medicine, University of Tsukuba
Department of Ophthalmology
305-8575
1-1-1 Tennoudai, Tsukuba, Ibaraki
029-853-3148
oshika@eye.ac
University of Tsukuba
Sugita Eye Clinic, Miyoshi Eye Clinic
Other
Sugita Eye Clinic, Miyoshi Eye Clinic
University of Tsukuba
1-1-1 Tennoudai,Tsukuba, Ibaraki
0298533148
oshika@eye.ac
YES
H30-297
University of Tsukuba
杉田眼科(東京都),三好眼科(広島県)
2019 | Year | 02 | Month | 24 | Day |
https://journals.lww.com/jcrs/pages/articleviewer.aspx?year=2023&issue=04000&article=00012&type=Full
Published
https://journals.lww.com/jcrs/pages/articleviewer.aspx?year=2023&issue=04000&article=00012&type=Full
22
Throughout the 12-month follow-up period, there was no significant difference in refractive and visual outcomes between groups. The amount of IOL decentration was significantly larger in eyes with CTR. There was a significant negative correlation between capsular bag diameter and the amount of IOL decentration in eyes with CTR, but not in eyes without CTR. CTR coimplantation increased IOL decentration possibly due to the interference between CTR eyelets and IOL haptics.
2023 | Year | 08 | Month | 29 | Day |
patients with bilateral cataract
patients at the outpatient clinic
none
clinical outcomes
Completed
2019 | Year | 02 | Month | 24 | Day |
2019 | Year | 02 | Month | 07 | Day |
2019 | Year | 02 | Month | 10 | Day |
2020 | Year | 12 | Month | 31 | Day |
2023 | Year | 08 | Month | 29 | Day |
2023 | Year | 08 | Month | 29 | Day |
2023 | Year | 08 | Month | 29 | Day |
2019 | Year | 02 | Month | 24 | Day |
2023 | Year | 08 | Month | 29 | Day |
Value
https://center6.umin.ac.jp/cgi-open-bin/ctr_e/ctr_view.cgi?recptno=R000040999