| Recruitment status | Completed |
| Unique ID issued by UMIN | UMIN000034862 |
| Receipt No. | R000039722 |
| Official scientific title of the study | Effect of manifest spherical equivalent error on visual acuity at various distances in eyes with a trifocal intraocular lens (IOL): a simulation study |
| Date of disclosure of the study information | 2018/11/12 |
| Last modified on | 2018/11/12 (Ver. 1) |
| Basic information | ||
| Official scientific title of the study | Effect of manifest spherical equivalent error on visual acuity at various distances in eyes with a trifocal intraocular lens (IOL): a simulation study | |
| Title of the study (Brief title) | Effect of spherical equivalent error on trifocal intraocular lens | |
| Region |
|
|
| Condition | ||
| Condition | Cataract | |
| Classification by specialty |
|
|
| Classification by malignancy | Others | |
| Genomic information | NO | |
| Objectives | |
| Narrative objectives1 | To examine the effect of manifest spherical equivalent error on all-distance visual acuity (VA) in eyes that received a trifocal IOL (Alcon PanOptix; TFT00) after simulating spherical equivalent error by adding various degrees of spherical lens. |
| Basic objectives2 | Others |
| Basic objectives -Others | Nearsightedness, emmetropia and hypermetropia are simulated by adding various degrees of spherical lens. and the visual acuity (VA) which can be put in those refraction states is measured. |
| Trial characteristics_1 | Exploratory |
| Trial characteristics_2 | Pragmatic |
| Developmental phase | Not applicable |
| Assessment | |
| Primary outcomes | Monocular corrected visual acuity (VA) at various distances was measured using the all-distance vision tester (KOWA AS-15) after simulation of spherical equivalent error.
1) +1.0D addition simulating -1.0D myopia 2) +0.5D addition simulating -0.5D myopia 3) 0D addition simulating emmetropia 4)-0.5D addition simulating +0.5D hyperopia 5) -1.0D addition simulating +1.0D hyperopia |
| Key secondary outcomes | Pupil diameter, corneal astigmatism, manifest spherical equivalent value |
| Base | |
| Study type | Observational |
| Study design | |
| Basic design | |
| Randomization | |
| Randomization unit | |
| Blinding | |
| Control | |
| Stratification | |
| Dynamic allocation | |
| Institution consideration | |
| Blocking | |
| Concealment | |
| Intervention | |
| No. of arms | |
| Purpose of intervention | |
| Type of intervention | |
| Interventions/Control_1 | |
| Interventions/Control_2 | |
| Interventions/Control_3 | |
| Interventions/Control_4 | |
| Interventions/Control_5 | |
| Interventions/Control_6 | |
| Interventions/Control_7 | |
| Interventions/Control_8 | |
| Interventions/Control_9 | |
| Interventions/Control_10 | |
| Eligibility | ||||
| Age-lower limit |
|
|||
| Age-upper limit |
|
|||
| Gender | Male and Female | |||
| Key inclusion criteria | Sixty eyes of 30 patients who underwent bilateral implantation of a trifocal IOL (Alcon PanOptix; TFNT00) were enrolled | |||
| Key exclusion criteria | Preoperative exclusion criteria were patients with any pathology of the cornea, macula, or optic nerve; opaque media other than cataract; history of ocular inflammation or surgery; corneal astigmatism of 1.0 D or more; marked irregular corneal astigmatism; amblyopia; and any difficulties with examinations or follow-up. Intraoperative exclusion criteria were a small pupillary diameter that required pupil expansion procedures and eventful surgery. | |||
| Target sample size | 30 | |||
| Research contact person | |
| Name of lead principal investigator | Ken Hayashi |
| Organization | Hayashi Eye Hospital |
| Division name | Department of Ophthalmology |
| Address | 4-23-35, Hakataekimae, Hakata-ku,Fukuoka, Japan |
| TEL | 092-431-1680 |
| hayashi-ken@hayashi.or.jp | |
| Public contact | |
| Name of contact person | Ken Hayashi |
| Organization | Hayashi Eye Hospital |
| Division name | Department of Ophthalmology |
| Address | 4-23-35, Hakataekimae, Hakata-ku, Fukuoka, Japan |
| TEL | 092-431-1680 |
| Homepage URL | http://www.hayashi.or.jp/hospital/chiken.html |
| hayashi-ken@hayashi.or.jp | |
| Sponsor | |
| Institute | Hayashi Eye Hospital |
| Institute | |
| Department | |
| Funding Source | |
| Organization | None |
| Organization | |
| Division | |
| Category of Funding Organization | Self funding |
| Nationality of Funding Organization | Japan |
| Other related organizations | |
| Co-sponsor | |
| Name of secondary funder(s) | |
| Secondary IDs | |
| Secondary IDs | NO |
| Study ID_1 | |
| Org. issuing International ID_1 | |
| Study ID_2 | |
| Org. issuing International ID_2 | |
| IND to MHLW | |
| Institutions | |
| Institutions | 林眼科病院(福岡県) Hayashi Eye Hospital (Fukuoka) |
| Other administrative information | |||||||
| Date of disclosure of the study information |
|
||||||
| Progress | |||||||
| Recruitment status | Completed | ||||||
| Date of protocol fixation |
|
||||||
| Anticipated trial start date |
|
||||||
| Last follow-up date |
|
||||||
| Date of closure to data entry |
|
||||||
| Date trial data considered complete |
|
||||||
| Date analysis concluded |
|
||||||
| Related information | |
| URL releasing protocol | |
| Publication of results | Unpublished |
| URL releasing results | |
| Results | |
| Other related information | Sixty eyes of 30 patients who underwent bilateral implantation of the trifocal IOL was sequentially included in the study between June 13 and September 27, 2018. |
| Management information | |||||||
| Registered date |
|
||||||
| Last modified on |
|
||||||
| Link to view the page | |
| URL(English) | https://upload.umin.ac.jp/cgi-open-bin/ctr_e/ctr_view.cgi?recptno=R000039722 |