| Recruitment status | Main results already published |
| Unique ID issued by UMIN | UMIN000032085 |
| Receipt No. | R000036603 |
| Scientific Title | A retrospective observational study investigating the change of transvalvular peak velocity among patients undergoing aortic valve replacement with bioprosthetic valve. |
| Date of disclosure of the study information | 2018/05/01 |
| Last modified on | 2021/06/04 (Ver. 12) |
| Basic information | ||
| Public title | A retrospective observational study investigating the change of transvalvular peak velocity among patients undergoing aortic valve replacement with bioprosthetic valve. | |
| Acronym | AVR TEE study | |
| Scientific Title | A retrospective observational study investigating the change of transvalvular peak velocity among patients undergoing aortic valve replacement with bioprosthetic valve. | |
| Scientific Title:Acronym | AVR TEE study | |
| Region |
|
|
| Condition | ||||
| Condition | Patients undergoing aortic valve replacement with bioprosthetic valve. | |||
| Classification by specialty |
|
|||
| Classification by malignancy | Others | |||
| Genomic information | NO | |||
| Objectives | |
| Narrative objectives1 | Aortic valve replacement (AVR) is an established procedure for treating aortic valvular diseases. Prosthesis-patient mismatch(PPM)is known as the factor increasing the postoperative mortality and morbidity. If intraoperative measurement of transvalvular peak velocity could predict postoperative PPM, intraoperative diagnosis and additional intervention may prevent postoperative PPM. |
| Basic objectives2 | Efficacy |
| Basic objectives -Others | |
| Trial characteristics_1 | |
| Trial characteristics_2 | |
| Developmental phase | |
| Assessment | |
| Primary outcomes | The interactions between time series variation of an adjusted peak trans-prosthetic valvular velocity and an intraoperative peak trans-prosthetic valvular velocity. |
| Key secondary outcomes | The interaction between time series variation of an adjusted peak trans-prosthetic valvular velocity and an implanted bio-prosthetic valve size, or a type of the implanted bio-prosthetic valve. |
| Base | |
| Study type | Observational |
| Study design | |
| Basic design | |
| Randomization | |
| Randomization unit | |
| Blinding | |
| Control | |
| Stratification | |
| Dynamic allocation | |
| Institution consideration | |
| Blocking | |
| Concealment | |
| Intervention | |
| No. of arms | |
| Purpose of intervention | |
| Type of intervention | |
| Interventions/Control_1 | |
| Interventions/Control_2 | |
| Interventions/Control_3 | |
| Interventions/Control_4 | |
| Interventions/Control_5 | |
| Interventions/Control_6 | |
| Interventions/Control_7 | |
| Interventions/Control_8 | |
| Interventions/Control_9 | |
| Interventions/Control_10 | |
| Eligibility | ||||
| Age-lower limit |
|
|||
| Age-upper limit |
|
|||
| Gender | Male and Female | |||
| Key inclusion criteria | Patient undergoing aortic valve replacement with bioprosthetic valve. | |||
| Key exclusion criteria | none | |||
| Target sample size | 700 | |||
| Research contact person | |||||||
| Name of lead principal investigator |
|
||||||
| Organization | National Cerebral and Cardiovascular Center | ||||||
| Division name | Department of Surgical Intensive Care | ||||||
| Zip code | 565-8565 | ||||||
| Address | 5-7-1 Fujishirodai, Suita, Osaka, Japan | ||||||
| TEL | 06-6833-5012 | ||||||
| nann_5115@ybb.ne.jp | |||||||
| Public contact | |||||||
| Name of contact person |
|
||||||
| Organization | National Cerebral and Cardiovascular Center | ||||||
| Division name | Department of Surgical Intensive Care | ||||||
| Zip code | 565-8565 | ||||||
| Address | 5-7-1 Fujishirodai, Suita, Osaka, Japan | ||||||
| TEL | 06-6833-5012 | ||||||
| Homepage URL | |||||||
| nann_5115@ybb.ne.jp | |||||||
| Sponsor | |
| Institute | National Cerebral and Cardiovascular Center |
| Institute | |
| Department | |
| Funding Source | |
| Organization | National Cerebral and Cardiovascular Center |
| Organization | |
| Division | |
| Category of Funding Organization | Self funding |
| Nationality of Funding Organization | |
| Other related organizations | |
| Co-sponsor | |
| Name of secondary funder(s) | |
| IRB Contact (For public release) | |
| Organization | National Cerebral and Cardiovascular Center |
| Address | 5-7-1 Fujishirodai, Suita, Osaka, Japan |
| Tel | 06-6833-5012 |
| k.minami@ncvc.go.jp | |
| Secondary IDs | |
| Secondary IDs | NO |
| Study ID_1 | |
| Org. issuing International ID_1 | |
| Study ID_2 | |
| Org. issuing International ID_2 | |
| IND to MHLW | |
| Institutions | |
| Institutions | |
| Other administrative information | |||||||
| Date of disclosure of the study information |
|
||||||
| Related information | |
| URL releasing protocol | https://www.jcvaonline.com/article/S1053-0770(19)30512-9/fulltext |
| Publication of results | Published |
| Result | |||||||
| URL related to results and publications | https://www.jcvaonline.com/article/S1053-0770(19)30512-9/fulltext | ||||||
| Number of participants that the trial has enrolled | 556 | ||||||
| Results | A multivariable logistic regression model was used to identify the predictors of patient-prosthesis mismatch at 1 year. There was no significant association between intraoperative peak velocity and peak velocity at 1 month (p = 0.419) or 1 year (p = 0.115). The implanted valve type (p < 0.001) and size (p < 0.001), but not intraoperative peak velocity (p = 0.503), were independent predictors of patient-prosthesis mismatch. | ||||||
| Results date posted |
|
||||||
| Results Delayed | |||||||
| Results Delay Reason | |||||||
| Date of the first journal publication of results | |||||||
| Baseline Characteristics | The study comprised 556 patients who underwent aortic valve replacement with a bioprosthetic valve. | ||||||
| Participant flow | Retrospectively reviewed from clinical record. | ||||||
| Adverse events | None. | ||||||
| Outcome measures | The associations between peak velocity values at the aforementioned 3 time points were analyzed using a multivariable nonlinear regression model. A multivariable logistic regression model was used to identify the predictors of patient-prosthesis mismatch at 1 year. | ||||||
| Plan to share IPD | |||||||
| IPD sharing Plan description | |||||||
| Progress | |||||||
| Recruitment status | Main results already published | ||||||
| Date of protocol fixation |
|
||||||
| Date of IRB |
|
||||||
| Anticipated trial start date |
|
||||||
| Last follow-up date |
|
||||||
| Date of closure to data entry |
|
||||||
| Date trial data considered complete |
|
||||||
| Date analysis concluded |
|
||||||
| Other | |
| Other related information | Intraoperative trans-prosthetic valvular peak velocity, postoperative trans-prosthetic valvular peak velocity were extracted from medical record. Trans-prosthetic valvular peak velocity were adjusted for age, sex, body surface area, size of implanted bio-prosthetic valve, type of implanted bio-prosthetic valve, presence or absence of aortic insufficiency, morphology of aortic valve (tricuspid or bicuspid valve), and preoperative stroke volume. The interaction between time-series variation of peak trans-prosthetic valvular velocity and intraoperative peak trans-prosthetic valvular velocity was assessed using a linear regression model adjusted by the Huber-White method for repeated measures data. |
| Management information | |||||||
| Registered date |
|
||||||
| Last modified on |
|
||||||
| Link to view the page | |
| URL(English) | https://upload.umin.ac.jp/cgi-open-bin/ctr_e/ctr_view.cgi?recptno=R000036603 |