Unique ID issued by UMIN | UMIN000030683 |
---|---|
Receipt number | R000035032 |
Scientific Title | Comparison of the clinical efficacy of salbutamol with jet and mesh nebulizers in asthmatic children |
Date of disclosure of the study information | 2018/01/05 |
Last modified on | 2018/01/05 14:54:08 |
Comparison of the clinical efficacy of salbutamol with jet and mesh nebulizers in asthmatic children
Mesh and jet nebulizers in asthma.
Comparison of the clinical efficacy of salbutamol with jet and mesh nebulizers in asthmatic children
Mesh and jet nebulizers in asthma.
Japan |
Asthmatic children
Pediatrics |
Others
NO
To estimmate the usefulness of mesh nebulizer on child asthmatic attacks.
Others
To estimate the usefulness on clinical phase.
Confirmatory
Pragmatic
Not applicable
This study included 88 patients <6 years of age who were treated for mild asthma attacks
at Maruyama Pediatric Clinic between October 2003 and January 2004,
After informed consent, patients were randomly assigned to receive treatment with either a mesh- or jet-type electronic nebulizer. For children <2 years old (n=37), a total volume of 1 mL was used, comprising 0.1 mL of salbutamol inhalation solution and 0.9 mL of saline. For children 2 years old (n=51), the total volume was 1 mL, comprising 0.2 mL of salbutamol inhalation solution and 0.8 mL of saline. Pre and post clinical symptom score, Saturation and Heart rate were examined.
Interventional
Parallel
Randomized
Cluster
Open -but assessor(s) are blinded
Placebo
YES
YES
YES
Pseudo-randomization
3
Treatment
Device,equipment |
By mesh type and jet type nebulizer, salbutamol inhalation
Age and Salbutamol; <2 years 0.1ml, >2 years 0.2 ml.
From Oct 2003 to Jan 2004.
2 | years-old | <= |
2 | years-old | > |
Male and Female
Child patients with asthma attack on Murayama Pediatrics.
None.
100
1st name | |
Middle name | |
Last name | Norihide Murayama |
Murayama Pediatrics
Pediatrics
3-2-33 Nagayoshi-Nagahara-Higashi Hirano-ku Osaka-shi Osaka Japan
06-6790-8835
norihide99@yahoo.co.jp
1st name | |
Middle name | |
Last name | Norihide Murayama |
Murayama Pediatrics
Pediatrics
3-2-33 Nagayoshi-Nagahara-Higashi Hirano-ku Osaka
06-6790-8835
norihide99@yahoo.co.jp
Murayama Pediatrics
Murayama Pediatrics
Self funding
NO
村山小児科(大阪府)
2018 | Year | 01 | Month | 05 | Day |
Unpublished
Inhalation times were significantly short with mesh type than jet type nebulizer.
Completed
2003 | Year | 09 | Month | 30 | Day |
2003 | Year | 10 | Month | 01 | Day |
2004 | Year | 01 | Month | 31 | Day |
2004 | Year | 01 | Month | 31 | Day |
2004 | Year | 01 | Month | 31 | Day |
2016 | Year | 01 | Month | 31 | Day |
In <2 years and >2 years groups there is no significant clinical improvement between mesh and jet nebulizers.
In >2 years of both mesh and jet group, heart rates were significantly increased after inhalation.
2018 | Year | 01 | Month | 04 | Day |
2018 | Year | 01 | Month | 05 | Day |
Value