Unique ID issued by UMIN | UMIN000028371 |
---|---|
Receipt number | R000032479 |
Scientific Title | Optimizing the detection methods for atrial fibrillation with irregular heartbeat detector during automated blood pressure measurement. |
Date of disclosure of the study information | 2017/07/28 |
Last modified on | 2018/08/22 12:54:37 |
Optimizing the detection methods for atrial fibrillation with irregular heartbeat detector during automated blood pressure measurement.
Optimizing the detection methods for atrial fibrillation with irregular heartbeat detector during automated blood pressure measurement.
Optimizing the detection methods for atrial fibrillation with irregular heartbeat detector during automated blood pressure measurement.
Optimizing the detection methods for atrial fibrillation with irregular heartbeat detector during automated blood pressure measurement.
Japan |
Atrial Fibrillation
Medicine in general | Cardiology |
Others
NO
A purpose of this study is to decide the most appropriate number of blood pressure measurements and irregular heartbeat occurrences for atrial fibrillation detection by using an automated blood pressure monitor with irregular heartbeat detector.
Efficacy
We use the Omron blood pressure monitor HME-907 and evaluate the performance (sensitivity, specificity, positive predictive value, negative predictive value, and accuracy) for detecting atrial fibrillation when irregular heartbeat is recorded at least once during three times of blood pressure measurements.
We make the diagnosis of the atrial fibrillation based on the characteristic views (the uncertainty of the RR interval, disappearance of the P wave, appearance of the fibrillation wave) in the monitor electrocardiogram wave pattern.
We evaluate the performance for detecting atrial fibrillation by the following conditions.
1. Comparison by the number of measurement (once, twice, three times).
2. Comparison by the number of the irregular heart beat (once, twice, more than three times).
3. Comparison of the volume of the pulse pressure.
Observational
20 | years-old | <= |
Not applicable |
Male and Female
Patients who are hospitalized or visit outpatient clinic in Kagawa University Hospital.
Patients who enter healthcare facilities for seniors in Kagawa.
Patients who cannot maintain rest in a sitting position.
Patients who are inappropriate to measure blood pressure in an upper arm such as dialysis patients.
Patients with pacemakers or defibrillators.
Patients judged unsuitable as subjects.
300
1st name | |
Middle name | |
Last name | Tetsuo Minamino |
School of Medicine, Kagawa University
Department of Cardiorenal and Cerebrovascular Medicine
1750-1 Ikenobe, Miki-cho, Kita-gun, Kagawa, Japan
+81-87-891-2150
minamino@med.kagawa-u.ac.jp
1st name | |
Middle name | |
Last name | Makoto Ishizawa |
School of Medicine, Kagawa University
Department of Cardiorenal and Cerebrovascular Medicine
1750-1 Ikenobe, Miki-cho, Kita-gun, Kagawa, Japan
+81-87-891-2150
ishizawa@med.kagawa-u.ac.jp
Kagawa University
OMRON HEALTHCARE Co., Ltd
Profit organization
NO
香川大学医学部附属病院(香川県)
2017 | Year | 07 | Month | 28 | Day |
Unpublished
Completed
2017 | Year | 02 | Month | 17 | Day |
2017 | Year | 04 | Month | 14 | Day |
2018 | Year | 06 | Month | 30 | Day |
Several blood pressure (BP) monitors include an irregular heartbeat detector, and Omron HME-907 is one of them. An irregular heartbeat is defined as a rhythm that varies more than 25% from the average rhythm detected while the monitor is measuring blood pressure. If atrial fibrillation can be appropriately detected by using the BP monitor with irregular heartbeat detector, it may lead to early diagnosis of atrial fibrillation. Some reports demonstrated the precision of atrial fibrillation detection in the past, but these reports showed different results. These differences may be caused by variation of patient profile or non-optimization of the measurement condition.
2017 | Year | 07 | Month | 25 | Day |
2018 | Year | 08 | Month | 22 | Day |