| Recruitment status | Completed |
| Unique ID issued by UMIN | UMIN000027671 |
| Receipt No. | R000031406 |
| Scientific Title | Accuracy of pulse-oximetry under INTELLiVENT-ASV |
| Date of disclosure of the study information | 2017/06/09 |
| Last modified on | 2021/04/28 (Ver. 5) |
| Basic information | ||
| Public title | Accuracy of pulse-oximetry under INTELLiVENT-ASV | |
| Acronym | Accuracy of SpO2 under i-ASV | |
| Scientific Title | Accuracy of pulse-oximetry under INTELLiVENT-ASV | |
| Scientific Title:Acronym | Accuracy of SpO2 under i-ASV | |
| Region |
|
|
| Condition | ||
| Condition | Critically ill patients under mechanical ventilation | |
| Classification by specialty |
|
|
| Classification by malignancy | Others | |
| Genomic information | NO | |
| Objectives | |
| Narrative objectives1 | INTLLiVENT-ASV (available on Hamilton G5) is a closed-loop ventilatory mode that provides adequate ventilatory support by using patient information. In this ventilation mode, for example, FIO2 and PEEP are automatically adjusted according to the value of patient's SpO2. There are some reports, however, that the value of SpO2 sometimes dissociates from SaO2 among various critically ill states. Therefore, accuracy of SpO2 is a prerequisite to use this mode, but to date, there is no study to evaluate the accuracy of SpO2 (Hamilton G5) among various critically ill states.
In this study, we aim to evaluate the accuracy of SpO2 by measuring three commercially available products (Hamilton G5, Masimo and NIHON-KODEN) and comparing with SpO2. |
| Basic objectives2 | Efficacy |
| Basic objectives -Others | |
| Trial characteristics_1 | |
| Trial characteristics_2 | |
| Developmental phase | |
| Assessment | |
| Primary outcomes | Accuracy between SpO2 and SaO2 |
| Key secondary outcomes | |
| Base | |
| Study type | Observational |
| Study design | |
| Basic design | |
| Randomization | |
| Randomization unit | |
| Blinding | |
| Control | |
| Stratification | |
| Dynamic allocation | |
| Institution consideration | |
| Blocking | |
| Concealment | |
| Intervention | |
| No. of arms | |
| Purpose of intervention | |
| Type of intervention | |
| Interventions/Control_1 | |
| Interventions/Control_2 | |
| Interventions/Control_3 | |
| Interventions/Control_4 | |
| Interventions/Control_5 | |
| Interventions/Control_6 | |
| Interventions/Control_7 | |
| Interventions/Control_8 | |
| Interventions/Control_9 | |
| Interventions/Control_10 | |
| Eligibility | ||||
| Age-lower limit |
|
|||
| Age-upper limit |
|
|||
| Gender | Male and Female | |||
| Key inclusion criteria | Patients were eligible for enrollment if they were 20 years or older, required mechanical ventilation and admitted to the ICU | |||
| Key exclusion criteria | 1. patients who can not measure pulse oximeter with fingers.
2. in case of an unreliable pulsatile SpO2 curve 3. patients who are under 20 years old. 4. patients who can not obtain the consent. 5. patients who undergo extracorporeal membrane oxygenation. 6 patients if carboxyhemoglobin (COHb) levels were > 3% or methemoglobin (MetHb) > 1.5% |
|||
| Target sample size | 100 | |||
| Research contact person | |||||||
| Name of lead principal investigator |
|
||||||
| Organization | Jichi Medical University School of Medicine | ||||||
| Division name | Department of Anesthesiology and Intensive Care Medicine | ||||||
| Zip code | 329-0498 | ||||||
| Address | 3311-1, Yakushiji, Shimotsuke, Tochigi, 329-0498, Japan | ||||||
| TEL | 0285-58-7392 | ||||||
| shinsyu_k@jichi.ac.jp | |||||||
| Public contact | |||||||
| Name of contact person |
|
||||||
| Organization | Jichi Medical University School of Medicine | ||||||
| Division name | Department of Anesthesiology and Intensive Care Medicine | ||||||
| Zip code | 329-0498 | ||||||
| Address | 3311-1, Yakushiji, Shimotsuke, Tochigi, 329-0498, Japan | ||||||
| TEL | 0285-58-7392 | ||||||
| Homepage URL | |||||||
| shinsyu_k@jichi.ac.jp | |||||||
| Sponsor | |
| Institute | Jichi Medical University School of Medicine |
| Institute | |
| Department | |
| Funding Source | |
| Organization | None |
| Organization | |
| Division | |
| Category of Funding Organization | Other |
| Nationality of Funding Organization | |
| Other related organizations | |
| Co-sponsor | |
| Name of secondary funder(s) | |
| IRB Contact (For public release) | |
| Organization | Department of Anesthesiology and Intensive Care Medicine, Jichi Medical University School of Medicine |
| Address | 3311-1, Yakushiji, Shimotsuke, Tochigi, 329-0498, Japan |
| Tel | 0285-58-7392 |
| shinsyu_k@jichi.ac.jp | |
| Secondary IDs | |
| Secondary IDs | NO |
| Study ID_1 | |
| Org. issuing International ID_1 | |
| Study ID_2 | |
| Org. issuing International ID_2 | |
| IND to MHLW | |
| Institutions | |
| Institutions | |
| Other administrative information | |||||||
| Date of disclosure of the study information |
|
||||||
| Related information | |
| URL releasing protocol | https://www.nature.com/articles/s41598-021-88608-7 |
| Publication of results | Published |
| Result | |||||||
| URL related to results and publications | https://www.nature.com/articles/s41598-021-88608-7 | ||||||
| Number of participants that the trial has enrolled | 100 | ||||||
| Results | Mean SaO2 values, Nihon Kohden SpO2, and Masimo SpO2 were 95.7%, 96.4%, and 96.9%, respectively. The Nihon Kohden SpO2 were less biased than Masimo measurements; their precision was not significantly different. Nihon Kohden and Masimo SpO2 were not significantly different in the SaO2 < 94% group (P = 0.083). In the 94% <= SaO2 < 98% and SaO2 >= 98% groups, there were significant differences between the Nihon Kohden and Masimo SpO2 (P < 0.0001; P = 0.006; respectively). | ||||||
| Results date posted |
|
||||||
| Results Delayed | |||||||
| Results Delay Reason | |||||||
| Date of the first journal publication of results | |||||||
| Baseline Characteristics | Patients were eligible for enrolment if they were >= 20 years old and ventilated with a G5 during their ICU stay. The exclusion criteria were age < 20 years, quality index of Nihon Kohden SpO2<= 60%, an unstable value of SpO2 due to change in FIO2 just before the blood sample was drawn, lack of SpO2 data, and a history of management with veno-arterial extracorporeal membrane oxygenation. In addition, patients with a difference of >10% in SpO2 and SaO2 values were excluded due to the possibility of outliers. For validation purposes, we added the analysis of the raw data, including data of the possible outliers. | ||||||
| Participant flow | Patients who were ventilated with a G5 ventilator (Hamilton Medical AG, Switzerland) in the ICU were included in this study. | ||||||
| Adverse events | No adverse events | ||||||
| Outcome measures | Patient baseline characteristics, including age, sex, height, body weight, body mass index, disease classifica- tion, and the use of veno-venous extracorporeal membrane oxygenation, were collected from electronic medi- cal records. In addition, the results of blood gas analyses, including pH, PaO2, arterial carbon dioxide tension, haemoglobin, and SaO2 values, were recorded. Furthermore, the PaO2/FIO2 ratio and severity of hypoxaemia were determined. Underlying medical histories were obtained, including information on hypertension, ischaemic heart disease, chronic heart failure, chronic obstructive pulmonary disease, cerebrovascular accidents, diabetes mellitus, and chronic kidney disease requiring haemodialysis. The Acute Physiology and Chronic Health Evalu- ation II19 was used to assess organ dysfunction. ICU stays and mechanical ventilation durations were evaluated. In addition, ICU and hospital mortality rates were assessed. | ||||||
| Plan to share IPD | |||||||
| IPD sharing Plan description | |||||||
| Progress | |||||||
| Recruitment status | Completed | ||||||
| Date of protocol fixation |
|
||||||
| Date of IRB |
|
||||||
| Anticipated trial start date |
|
||||||
| Last follow-up date |
|
||||||
| Date of closure to data entry | |||||||
| Date trial data considered complete | |||||||
| Date analysis concluded | |||||||
| Other | |
| Other related information | Not applicable |
| Management information | |||||||
| Registered date |
|
||||||
| Last modified on |
|
||||||
| Link to view the page | |
| URL(English) | https://upload.umin.ac.jp/cgi-open-bin/ctr_e/ctr_view.cgi?recptno=R000031406 |