Unique ID issued by UMIN | UMIN000026780 |
---|---|
Receipt number | R000030734 |
Scientific Title | Comparison of Insulin glargine U-300 vs Insulin degludec using FreeStyle Libre Pro:randomised crossover study |
Date of disclosure of the study information | 2017/04/01 |
Last modified on | 2020/07/05 13:20:37 |
Comparison of Insulin glargine U-300 vs Insulin degludec using FreeStyle Libre Pro:randomised crossover study
Comparison of Insulin glargine U-300 vs Insulin degludec using FreeStyle Libre Pro:randomised crossover study
Comparison of Insulin glargine U-300 vs Insulin degludec using FreeStyle Libre Pro:randomised crossover study
Comparison of Insulin glargine U-300 vs Insulin degludec using FreeStyle Libre Pro:randomised crossover study
Japan |
diabetes
Endocrinology and Metabolism |
Others
NO
Examine the safety and efficacy of insulin glargine U-300 and insulin degludec
Safety
<70mg/dL hypoglycemia
CV-value
mean glucose level,SD
M-value,MODD,
<54mg/dL hypogliycemia
Interventional
Cross-over
Randomized
Individual
Open -no one is blinded
Active
Numbered container method
4
Treatment
Medicine | Device,equipment |
Type 2 diabetes patients using degludec were assigned to glargin U-300 group and degludec group by the envelope method, each patient was fitted with Libre Pro and targeted to the pre-breakfast blood glucose of 100 mg / dl, the patient self- Titration is done for one week (adjustment period).
The dose is fixed for the next week and the blood glucose level of Libre Pro is evaluated (evaluation period)
Preliminary treatment basal insulin is switched to glargine U-300, degludec 1 week before each patient was fitted with Libre Pro and targeted to the pre-breakfast blood glucose of 100 mg / dl, the patient self- Titration is done for one week (adjustment period)
The dose is fixed for the next week and the blood glucose level of Libre Pro is evaluated (evaluation period)
20 | years-old | <= |
90 | years-old | >= |
Male and Female
40 patients with type 2 diabetes using insulin degludec (excluding patients with additional insulin)
Severe renal dysfunction
Judged to be unsuitable for participation for medical reasons
40
1st name | Mizuho |
Middle name | |
Last name | Yamabe |
Murakami Memorial Hospital
Department of Diabetes Internal medicine
7220014
1-14-26,shinhama,Onomichi-city, Hiroshima,722-0014,Japan
0848-22-3131
mk-hp2@able.ocn.ne.jp
1st name | Mizuho |
Middle name | |
Last name | Yamabe |
Murakami Memorial Hospital
Department of Diabetes Internal medicine
7220014
1-14-26,shinhama,Onomichi-city, Hiroshima,722-0014,Japan
0848-22-3131
mk-hp2@able.ocn.ne.jp
Murakami Memorial Hosupital
None
Self funding
Murakami Memorial Hospital
1-14-26,shinhama,Onomichi-city, Hiroshima,722-0014,Japan
0848223131
mk-hp2@able.ocn.ne.jp
NO
2017 | Year | 04 | Month | 01 | Day |
https://onlinelibrary.wiley.com/journaljdi
Published
https://onlinelibrary.wiley.com/journaljdi
24
Glucose levels less than 70 mg/dL were not significantly different between the two insulin treatments. Nocturnal hypoglycemia with Gla300 was significantly lower than that with Deg treatment. Incidence of nocturnal hypoglycemia with Deg treatment was associated with the concomitant use of metformin.
2020 | Year | 07 | Month | 05 | Day |
2018 | Year | 07 | Month | 10 | Day |
24 Japanese patients with type 2 diabetes
We compared the efficacy and safety of insulin glargine 300 U/mL (Gla300) and insulin degludec U100 (Deg) using a flash glucose monitoring system.
None
The primary end-points were the mean percentage of time in the target glucose range (70~179 mg/dL) and hypoglycemia (less than 70 mg/dL), as measured using flash glucose monitoring during the last 7 days of each 14-day period
Completed
2017 | Year | 04 | Month | 01 | Day |
2017 | Year | 04 | Month | 01 | Day |
2017 | Year | 04 | Month | 01 | Day |
2017 | Year | 10 | Month | 01 | Day |
2017 | Year | 10 | Month | 01 | Day |
2017 | Year | 10 | Month | 01 | Day |
2017 | Year | 12 | Month | 01 | Day |
2017 | Year | 03 | Month | 30 | Day |
2020 | Year | 07 | Month | 05 | Day |
Value
https://center6.umin.ac.jp/cgi-open-bin/ctr_e/ctr_view.cgi?recptno=R000030734