Unique ID issued by UMIN | UMIN000025021 |
---|---|
Receipt number | R000026237 |
Scientific Title | Evaluation of tissue blood flow for limb ischemia by finger-mounted tissue oximetry |
Date of disclosure of the study information | 2016/11/28 |
Last modified on | 2019/07/19 15:10:54 |
Evaluation of tissue blood flow for limb ischemia by finger-mounted tissue oximetry
Evaluation of tissue blood flow for limb ischemia by finger-mounted tissue oximetry
Evaluation of tissue blood flow for limb ischemia by finger-mounted tissue oximetry
Evaluation of tissue blood flow for limb ischemia by finger-mounted tissue oximetry
Japan |
Peripheral Arterial Disease
Vascular surgery |
Others
NO
Conventionally, a non-invasive blood flow evaluation method of limb arterial disease such as obstructive arteriosclerosis and Buerger disease is used as a gold standard for ankle-ankle artery pressure ratio (ABI), and in recent years it has been reported that skin perfusion pressure (TcPO 2), percutaneous oxygen partial pressure (SPP) have also been clinically applied.However, these tests were time consuming and painful in some cases. The examination finger wearable oximeter is a device which is already on the market as an apparatus for evaluating the cerebral blood flow (brain tissue oxygen saturation) of fetus and newborn in a simple and short time on the principle of near infrared spectroscopy, It is said that blood flow can be measured anywhere as long as 5 mm from the body surface of the body. We will evaluate the blood flow of the ischemic limb using this apparatus and examine the correlation with the conventional method ABI and the superiority compared with TcPO 2 and SPP.
Efficacy
Comparison of measured value of rSO2 measured with a diagnostic finger wearing oximeter in the lower extremity with the conventional method (below)
Ankle-brachial artery pressure index (ABI)
Toe-brachial artery pressure index (TBI)
Percutaneous oxygen partial pressure (TcPO 2)
The average value of rSO 2 and T-HbI of healthy subjects and ischemic limb patients
Repeatability of repeated measurements of rSO 2, T-HbI
Interventional
Single arm
Non-randomized
Open -no one is blinded
Self control
1
Prevention
Device,equipment |
finger-mouted tissue oximetry, transcutaneous oxygen tension, skin perfusion pressure, ankle-brachial pressure index
20 | years-old | <= |
80 | years-old | >= |
Male and Female
1)healthy adult volunteers
2)patients with arteriosclerosis obliterans
1)Pregnant, possibly pregnant women
2)Patients who are assessed as not eligible for the study by the investigator
3)patients who do not agree
100
1st name | |
Middle name | |
Last name | Naoki Unno |
Hamamatsu University School of Medicine
Division of Vascular Surgery, Second Department of Surgery
1-20-1 Handayama, Higashi-Ku, Hamamatsu, Shizuoka
053-435-2279
unno@hama-med.ac.jp
1st name | |
Middle name | |
Last name | Kazunori Inuzuka |
Hamamatsu University School of Medicine
Division of Vascular Surgery, Second Department of Surgery
1-20-1 Handayama, Higashi-Ku, Hamamatsu, Shizuoka
053-435-2279
inu@hama-med.ac.jp
Division of Vascular Surgery, Second Department of Surgery, Hamamatsu University School of Medicine
Division of Vascular Surgery, Second Department of Surgery, Hamamatsu University School of Medicine
Self funding
NO
2016 | Year | 11 | Month | 28 | Day |
Unpublished
Enrolling by invitation
2016 | Year | 06 | Month | 16 | Day |
2016 | Year | 06 | Month | 13 | Day |
2016 | Year | 11 | Month | 28 | Day |
2021 | Year | 05 | Month | 31 | Day |
2021 | Year | 05 | Month | 31 | Day |
2016 | Year | 11 | Month | 28 | Day |
2019 | Year | 07 | Month | 19 | Day |
Value
https://center6.umin.ac.jp/cgi-open-bin/ctr_e/ctr_view.cgi?recptno=R000026237