| Scientific Title | Effects of neck rotation on left-sided double lumen tube positioning |
| Date of disclosure of the study information | 2016/04/12 |
| Last modified on | 2017/03/30 14:50:29 |
Effects of neck rotation on left-sided double lumen tube positioning
Effects of neck rotation on left-sided double lumen tube positioning
Effects of neck rotation on left-sided double lumen tube positioning
Effects of neck rotation on left-sided double lumen tube positioning
| Japan |
Differential lung ventilation
| Anesthesiology |
Others
NO
Compare the neck rotation and fiberoptic bronchoscopy guide as a correction method of left-sided double lumen tube malposition.
Efficacy
Success ratio of left bronchial intubation
Interventional
Cross-over
Randomized
Individual
Single blind -participants are blinded
Active
2
Treatment
| Maneuver |
Right rotation of the neck
Fiberoptic bronchoscopy guided insertion
| Not applicable |
| Not applicable |
Male and Female
Cases resulted in right sided malposition of left double lumen tube.
none
20
| 1st name | |
| Middle name | |
| Last name | Hiromi Katoh |
Hyogo Cancer Center
Department of Anesthesia
13-70 Kitaoji Akashi
0789291151
whoami@hp.pref.hyogo.jp
| 1st name | |
| Middle name | |
| Last name | Hiromi Katoh |
Hyogo Cancer Center
Department of Anesthesia
13-70 Kitaoji Akashi
0789291151
whoami@hp.pref.hyogo.jp
Department of Anesthesia
Hyogo Cancer Center
Department of Anesthesia
Hyogo Cancer Center
Local Government
Japan
NO
兵庫県立がんセンター
| 2016 | Year | 04 | Month | 12 | Day |
Published
https://confit.atlas.jp/guide/event/jsa64/static/64th_program
Twenty six cases resulted 26cases of misplacement into the left double lumen tube into the right bronchus. Optical bronchofiber scope guide corrected 24 of 26cases into the left bronchus. The right sided neck rotation also revealed 24 correct placement of bronchial tube into the left bronchus. The two failed cases were correctly placed by another method respectively.
The neck rotation was effective for correct positioning of left double lumen tube as bronchofiber guide, and these two method are suspected as complementary.
Completed
| 2016 | Year | 03 | Month | 09 | Day |
| 2016 | Year | 04 | Month | 13 | Day |
| 2017 | Year | 03 | Month | 30 | Day |
| 2017 | Year | 03 | Month | 30 | Day |
| 2017 | Year | 03 | Month | 30 | Day |
| 2017 | Year | 03 | Month | 30 | Day |
| 2016 | Year | 04 | Month | 12 | Day |
| 2017 | Year | 03 | Month | 30 | Day |
Value
https://center6.umin.ac.jp/cgi-open-bin/ctr_e/ctr_view.cgi?recptno=R000025240