Unique ID issued by UMIN | UMIN000014176 |
---|---|
Receipt number | R000016451 |
Scientific Title | The Effects of Predilation with Scoring Balloon Compared to Conventional Balloon on Everolimus-eluting Stent Expansion Analyzed with Optical Coherent Tomography |
Date of disclosure of the study information | 2014/06/06 |
Last modified on | 2015/10/10 22:55:14 |
The Effects of Predilation with Scoring Balloon Compared to Conventional Balloon on Everolimus-eluting Stent Expansion Analyzed with Optical Coherent Tomography
Scoring Compared to Conventional Ballooning on Everolimus-eluting Stent Expansion
The Effects of Predilation with Scoring Balloon Compared to Conventional Balloon on Everolimus-eluting Stent Expansion Analyzed with Optical Coherent Tomography
Scoring Compared to Conventional Ballooning on Everolimus-eluting Stent Expansion
Japan |
Coronary artery disease
Cardiology |
Others
NO
Stent expansion remains one of important predictors of restenosis and subacute thrombosis, even in use of the drug-eluting stent. In those patients, the role of different predilation strategies has yet to be established. Moreover, in the bioresorbable vascular scaffold era, sufficient lesion preparation is essential for their appropriate apposition. The aim of this study was to clarify the impact of lesion preparation using the scoring balloon on final stent expansion.
Efficacy
Rate of achieved to predicted stent area after deployment measured by optical coherent tomography (OCT)
i) Binary stent restenosis at remote phase (QCA)
ii) Target vessel diameter/area after balloon angioplasty (OCT)
iii) All-cause mortality, MACE (Major Adverse Cardiac Event)
Interventional
Parallel
Randomized
Individual
Open -no one is blinded
Active
2
Treatment
Device,equipment |
Non-calcified coronary artery atherosclerotic lesions (calcification <50% of circumference) predilated with semi-compliant conventional balloon followed by a single 2.5-3.0 mm Cobalt-chromium Everolimus-eluting stent deployment under optical coherent tomography (OCT) guidance without post-stenting dilation.
Non-calcified coronary artery atherosclerotic lesions (calcification <50% of circumference) predilated with semi-compliant Scoring balloon followed by a single 2.5-3.0 mm Cobalt-chromium Everolimus-eluting stent deployment under optical coherent tomography (OCT) guidance without post-stenting dilation.
20 | years-old | <= |
Not applicable |
Male and Female
Consecutive patients undergoing staged PCI in a single cardiovascular center.
(i) Referential vessel diameter estimated by OCT ((prox.+dist.)/2): 2.5-3.0 mm
(ii) Lesion that is able to be covered by a single stent
(iii) Lesion with calcification less than 50% of circumference
(i) Acute coronary syndrome
(ii) Pregnant patients
(iii) Patients with malignant neoplasm whose life expectancies of less than 6 months
(iv) Patients underwent prior PCI/CABG within 6 months
(v) Patients with decompensated heart failure
(vi) Patients with chronic kidney disease > stage 4
(vii) Patients with allergic reaction against ASA or clopidogrel
60
1st name | |
Middle name | |
Last name | Kentaro Jujo |
Nishiarai Heart Center Hospital
Department of Cardiology
1-12-8, Nishiarai Honcho, Adachi-ku, Tokyo, Japan
+81358380730
juken1123@hotmail.co.jp
1st name | |
Middle name | |
Last name | Kentaro Jujo |
Nishiarai Heart Center Hospital
Department of Cardiology
1-12-8, Nishiarai Honcho, Adachi-ku, Tokyo, Japan
+81358380730
juken1123@hotmail.co.jp
Nishiarai Heart Center Hospital
Nishiarai Heart Center Hospital
Self funding
NO
2014 | Year | 06 | Month | 06 | Day |
Unpublished
Completed
2012 | Year | 12 | Month | 01 | Day |
2013 | Year | 01 | Month | 01 | Day |
2014 | Year | 06 | Month | 05 | Day |
2015 | Year | 10 | Month | 10 | Day |