| Recruitment status | Completed |
| Unique ID issued by UMIN | UMIN000007764 |
| Receipt No. | R000009101 |
| Scientific Title | A Multicenter, Randomized Trial to Compare 2 link Nobori and 3 link Xience Stents in Bifurcation Stenting |
| Date of disclosure of the study information | 2012/04/16 |
| Last modified on | 2021/04/23 (Ver. 13) |
| Basic information | ||
| Public title | A Multicenter, Randomized Trial to Compare 2 link Nobori and 3 link Xience Stents in Bifurcation Stenting | |
| Acronym | Bifurcation stenting using 2 link stent Nobori versus
3 link stent Xience (BEGIN) |
|
| Scientific Title | A Multicenter, Randomized Trial to Compare 2 link Nobori and 3 link Xience Stents in Bifurcation Stenting | |
| Scientific Title:Acronym | Bifurcation stenting using 2 link stent Nobori versus
3 link stent Xience (BEGIN) |
|
| Region |
|
|
| Condition | ||
| Condition | Coronary artery disease with de novo true bifurcation lesions | |
| Classification by specialty |
|
|
| Classification by malignancy | Others | |
| Genomic information | NO | |
| Objectives | |
| Narrative objectives1 | To make a comparison of safety and efficacy of DESs with different link number (2-link Nobori and 3-link Xience/PROMUS) in patients with de novo true bifurcation lesions. |
| Basic objectives2 | Safety,Efficacy |
| Basic objectives -Others | |
| Trial characteristics_1 | |
| Trial characteristics_2 | |
| Developmental phase | |
| Assessment | |
| Primary outcomes | The minimum lumen diameter of the side branch ostium in bifurcation at 8 months after PCI.
Incidence of the Adverse events until one year after PCI. |
| Key secondary outcomes | |
| Base | |
| Study type | Interventional |
| Study design | |
| Basic design | Parallel |
| Randomization | Randomized |
| Randomization unit | Individual |
| Blinding | Open -no one is blinded |
| Control | Active |
| Stratification | |
| Dynamic allocation | |
| Institution consideration | |
| Blocking | |
| Concealment | |
| Intervention | ||
| No. of arms | 2 | |
| Purpose of intervention | Treatment | |
| Type of intervention |
|
|
| Interventions/Control_1 | 2-link biolimus-eluting stent (Nobori) | |
| Interventions/Control_2 | 3-link everolimus-eluting stent(Xience) | |
| Interventions/Control_3 | ||
| Interventions/Control_4 | ||
| Interventions/Control_5 | ||
| Interventions/Control_6 | ||
| Interventions/Control_7 | ||
| Interventions/Control_8 | ||
| Interventions/Control_9 | ||
| Interventions/Control_10 | ||
| Eligibility | ||||
| Age-lower limit |
|
|||
| Age-upper limit |
|
|||
| Gender | Male and Female | |||
| Key inclusion criteria | 1.Patient eligible for percutaneous coronary intervention
2. Patient or substitute decision-maker willing to provide written informed consent, which is approved by the Institutional Review Board or its equivalence 3. De novo stenosis at coronary bifurcation with up to two vessels (visually estimated diameter stenosis >= 50%). 4. Second vessel at coronary bifurcation treatable with trial device during the procedure 5. True coronary bifurcation, >=50% diameter stenosis in both the main and side branches, belonging to the Medina classes 1.1.1, 1.0.1, and 0.1.1 6. Visually estimated target lesion reference vessel diameter, 2.5-5.0 mm in the main branch, >=2.25 mm in the side branch 7. Target lesion treatable with one or two stents in both the main and side branches 8. Consensus of PCI after discussion between cardiologists and cardiac surgeons for the lesion in the left main coronary artery 9. Thrombolysis in Myocardial Infarction grade >=1 flow in both the main and side branches |
|||
| Key exclusion criteria | A. General restrictions
1. Unable to be followed by the implementing medical institution 2. Life expectancy <1 year 3. Acute myocardial infarction (<1 week) 4. Left ventricular ejection fraction < 30% 5. Scheduled for elective treatment requiring antiplatelet drug withdrawal 6. Deemed as unsuitable by the investigator or sub-investigator 7. Serum creatinine level >=2.0 mg/dl B. Vascular morphological restrictions 1. Lesion proximal to coronary artery bypass graft anastomotic site (visual estimation <=5.0 mm) or including a part of coronary artery bypass grafting 2. In-stent restenosis 3. Severe calcification |
|||
| Target sample size | 240 | |||
| Research contact person | |||||||
| Name of lead principal investigator |
|
||||||
| Organization | Saiseikai Yokohama City Eastern Hospital | ||||||
| Division name | Divison of Cardiology | ||||||
| Zip code | 045-576-3000 | ||||||
| Address | 3-6-1 Shimosueyoshi Tsurumi-ward, Yokohama, Japan | ||||||
| TEL | 045-576-3000 | ||||||
| bigin-trial@kchnet.or.jp | |||||||
| Public contact | |||||||
| Name of contact person |
|
||||||
| Organization | Kurashiki Central Hospital | ||||||
| Division name | Clinical Research Center | ||||||
| Zip code | 710-8602 | ||||||
| Address | 1-1-1 Miwa, Kurashiki city, Okayama, Japan | ||||||
| TEL | 086-422-0210 | ||||||
| Homepage URL | |||||||
| kenkyu@kchnet.or.jp | |||||||
| Sponsor | |
| Institute | BEGIN trial investigators |
| Institute | |
| Department | |
| Funding Source | |
| Organization | Kurashiki Central Hospital |
| Organization | |
| Division | |
| Category of Funding Organization | Non profit foundation |
| Nationality of Funding Organization | |
| Other related organizations | |
| Co-sponsor | |
| Name of secondary funder(s) | |
| IRB Contact (For public release) | |
| Organization | Kurashiki Central Hospital |
| Address | 1-1-1 Miwa, Kurashiki city, Okayama, Japan |
| Tel | 086-422-0210 |
| kenkyu@kchnet.or.jp | |
| Secondary IDs | |
| Secondary IDs | YES |
| Study ID_1 | NCT01574586 |
| Org. issuing International ID_1 | ClinicalTrials.gov |
| Study ID_2 | |
| Org. issuing International ID_2 | |
| IND to MHLW | |
| Institutions | |
| Institutions | |
| Other administrative information | |||||||
| Date of disclosure of the study information |
|
||||||
| Related information | |
| URL releasing protocol | https://doi.org/10.1007/s00380-019-01368-3 |
| Publication of results | Published |
| Result | |||||||
| URL related to results and publications | https://doi.org/10.1007/s00380-019-01368-3 | ||||||
| Number of participants that the trial has enrolled | 226 | ||||||
| Results | The primary endpoints (minimumlumen diameter at the SB ostium measured at an independent core laboratory at the 8-month follow-up) were comparable(1.64 +/- 0.50 mm vs. 1.63 +/- 0.51mm, p=0.976). There was no significant difference in composite outcomes of cardiac death,myocardial infarction, or target vascular revascularization at 12 months (7.4% vs. 8.0%, p = 0.894). Two-link BES and 3-link
EES showed similar 8-month angiographic and 1-year clinical outcomes for true CBLs. |
||||||
| Results date posted |
|
||||||
| Results Delayed | |||||||
| Results Delay Reason | |||||||
| Date of the first journal publication of results | |||||||
| Baseline Characteristics | Fortysix Japanese centers participated, of which 34 enrolled patients.Inclusion criteria were as follows: Patients over 20 years with (1) de novo and true CBLs, over 50% diameter stenosis (DS) in the MV and SB belonging to Medina classes (1.1.1), (1.0.1), and (0.1.1); (2) visually estimated target lesion reference vessel diameter (RVD), 2.5-5.0 mm in the MV, and over 2.25 mm in the SB;(3) target CBLs treatable with one or two stents in both branches (treatable within 4 stents in lesions including CBLs); and (4)Thrombolysis in Myocardial Infarction (TIMI) grade over 1 flow in both branches. CBLs were defined as lesions 10 mm proximal from the carina to the MV or 5 mm distal from the carina to the MV or SB on angiography.For the left main coronary artery (LMCA) lesions, PCI consensus was obtained after discussion between the cardiologists and cardiac surgeons. One target CBL per patient treated with the study device was enrolled. | ||||||
| Participant flow | After a baseline angiogram was obtained, the patients were randomly assigned in a 1:1 ratio to one of the two devices:
2-link BES (Nobori, TERUMO, Tokyo) and 3-link EES (Xience V, Prime, Xpedition, Abbott Vascular). |
||||||
| Adverse events | Major adverse cardiovascular events 17
Cardiac death 1 Non-cardiac death 0 Myocardial infarction 7 Target vessel revascularization 15 Target lesion revascularization 8 TLR for target bifurcation6 Stent thrombosis 3 |
||||||
| Outcome measures | The primary endpoint of the study was angiographic MLD
at the SBO at 8 months. The secondary endpoint was the occurrence of major adverse cardiac events (MACE) defined as the composite of cardiac death, Q-wave or non-Q-wave MI, or target vessel revascularization (TVR) at 12 months. |
||||||
| Plan to share IPD | |||||||
| IPD sharing Plan description | |||||||
| Progress | |||||||
| Recruitment status | Completed | ||||||
| Date of protocol fixation |
|
||||||
| Date of IRB |
|
||||||
| Anticipated trial start date |
|
||||||
| Last follow-up date |
|
||||||
| Date of closure to data entry | |||||||
| Date trial data considered complete | |||||||
| Date analysis concluded | |||||||
| Other | |
| Other related information | |
| Management information | |||||||
| Registered date |
|
||||||
| Last modified on |
|
||||||
| Link to view the page | |
| URL(English) | https://upload.umin.ac.jp/cgi-open-bin/icdr_e/ctr_view.cgi?recptno=R000009101 |