UMIN試験ID | UMIN000048473 |
---|---|
受付番号 | R000055237 |
科学的試験名 | 鍼刺激による予防的介入が視覚性動揺病に及ぼす影響:ランダム化比較試験による至適な鍼刺激条件の検討 |
一般公開日(本登録希望日) | 2022/07/27 |
最終更新日 | 2022/09/10 19:36:50 |
日本語
鍼刺激による予防的介入が視覚性動揺病に及ぼす影響:ランダム化比較試験による至適な鍼刺激条件の検討
英語
The preventive effect of acupuncture stimulation on optokinetic motion sickness: Examination of optimal acupuncture stimulation conditions in a randomized controlled trial
日本語
鍼刺激による予防的介入が視覚性動揺病に及ぼす影響
英語
The preventive effect of acupuncture stimulation on optokinetic motion sickness
日本語
鍼刺激による予防的介入が視覚性動揺病に及ぼす影響:ランダム化比較試験による至適な鍼刺激条件の検討
英語
The preventive effect of acupuncture stimulation on optokinetic motion sickness: Examination of optimal acupuncture stimulation conditions in a randomized controlled trial
日本語
鍼刺激による予防的介入が視覚性動揺病に及ぼす影響
英語
The preventive effect of acupuncture stimulation on optokinetic motion sickness
日本/Japan |
日本語
視覚性動揺病
悪心
英語
Optokinetic motion sickness
Nausea
内科学一般/Medicine in general | 消化器内科学(消化管)/Gastroenterology |
神経内科学/Neurology | 精神神経科学/Psychiatry |
成人/Adult |
悪性腫瘍以外/Others
いいえ/NO
日本語
本研究では、健常人にVirtual Reality(VR)システムを用いて視覚性動揺病を誘発させ、悪心を中心とする各種の自律神経症状に対する鍼刺激の予防効果および刺激条件の検討について、Sham鍼を用いたランダム化比較試験を行う。
英語
The aims of this study are to investigate the effect of acupuncture stimulation on optokinetic motion sickness had been induced by virtual reality (VR) system in healthy volunteers. We consider the preventive effect of acupuncture stimulation and optimal acupuncture stimulation conditions for various autonomic nervous symptoms such as nausea in a randomized controlled trial using sham needle.
有効性/Efficacy
日本語
英語
日本語
胃電図の測定方法は、ポータブル型胃電計EGS2(ニプロ社製)を用いて、ディスポーザブル銀-塩化銀電極(ビトロード Bs:日本光電社製)を胸骨剣状突起と臍との間を4等分し、上4分の1の高さで左右の肋骨弓下部に装着する。また電極装着の際には、皮膚の電気抵抗を落とすためにセロハンテープを用いて角質の除去を行う。胃電図の解析方法は、胃電計からsampling rate 1 HzでPCに取り込み、fast Fourie’s transform(FFT)を用いて周波数解析を256秒ごとに行う。これより描出されたpower spectrumから0-9 cycles/min.(cpm)のpower帯域を胃電図の出現し得る帯域とみなし、2-4 cpmを正常波帯域、それより遅い0-2 cpmを遅波帯域、それより早い4-9 cpmを速波帯域と定義し、それぞれのpowerの割合を算出する。測定は、鍼刺激前安静5分、VR負荷中15分の計20分間行う。
英語
The electrogastrogram (EGG) is measured using a portable EGG recorder (EGS2. Nipro Co., Japan). A disposable Ag-AgCl electrodes (Vitrode F, NIHON KODEN, Japan) are placed just under the left and right costal margin at the upper quarter level between the processus xiphoideus and the umbilicus. Moreover, the keratin is removed using tape to reduce the electrical resistance of the skin in before applying the electrodes. EGG data are transferred to a PC at a sampling rate of 1 Hz, then using a fast Fourie's transform (FFT), we compute an algorithm of a power spectra of every 256 sec. Each EGG recording divided into blocks of 60 sec without overlapping. On the power spectrum of each 60 sec, the dominant frequencies of EGG are defined under 0-9 cpm. The percentages of the normogastria range (2-4 cpm), the bradygastria range (0-2 cpm), and the tachygastria range (4-9 cpm) are calculated, respectively. EGG is measured for 20 minutes of 5 minutes at rest before acupuncture stimulation and 15 minutes during VR intervention.
日本語
心臓自律神経機能の測定方法は、電極を胸部第Ⅰ誘導で装着し、バイオアンプ(ML132, AD instruments)を用いて増幅させる。フィルターの設定はhigh cut filter 60 Hz、 時定数は0.03 secとする。心電図はA/D converter(PowerLab 8sp, AD Instruments)を介しsampling rate 1 kHzでPCに取り込み、解析ソフトChart5(PowerLab, AD Instruments)およびHRV moduleを用いてheart rate variability(HRV)解析を行う。FFT解析により得られたpower spectrumにおいて、0.05~0.15 Hzの帯域をlow frequency(LF)成分とし交感神経機能の指標に用い、0.15~0.4 Hzの帯域をhigh frequency(HF)成分とし副交感神経機能の指標とする。なお、今回はtotal powerに対するLFの占める割合(LF normalized unit: LFnu)およびHFの占める割合(HF normalized unit: HFnu)を求める。さらに、交感神経と副交感神経の相対的なバランスの指標として、LF成分とHF成分の比であるLF/HFを演算する。測定は、鍼刺激前安静5分、VR負荷中15分の計20分間行う。
悪心の評価は,症状のない場合を0点とし,嘔吐に至る状態を100点として、鍼刺激前、VR負荷前、VR負荷後の計3回聴取する。
動揺病症状の評価は、subjective symptom of motion sickness(SSMS)を用いる。SSMSは、動揺病に伴う、不快感、頭重感、熱感、発汗、眠気(うとうと感)、唾液過多、悪心の7項目からなる。それぞれの症状の程度に応じて、4・6段階の評価を行い、最小0点、最大49点となる。このSSMSをVR負荷時に相当する15分間に3分おきで聴取して、経時的な症状の推移を確認する。
英語
For the electrocardiogram (ECG), a disposable Ag-AgCl electrodes (Vitrode Bs, NIHON KODEN, Japan) are attached to the chest and amplified using a bio-amplifier (ML132, AD instruments, Australia). The filter settings are high cut filter 60 Hz and the time constant is 0.03 sec. The ECG is taken into a PC at a sampling rate of 1 kHz via an A / D converter (Power Lab 8sp, AD Instruments, Australia), and HRV analysis is used the analysis software Chart5 (AD Instruments, Australia) and HRV module. In the power spectrum obtained by FFT, 0.05-0.15 Hz power is defined as the low-frequency (LF) component, and 0.15-0.4 Hz power is defined as the high-frequency (HF) component. The ratios of LF and HF to the total power values are defined as normalized units of LF (LFnu) and normalized units of HF (HFnu). Moreover, LF / HF is calculated which is the ratio of the LF component and the HF component. The HFnu is used as the index for vagal activity and the LFnu is used as the index of sympathetic activity and the LF/HF ratio is used as the index of sympatho-vagal balance. The measurement is performed for a total of 20 minutes of 5 minutes before acupuncture stimulation and 15 minutes during VR intervention.
The evaluation of nausea is performed with 0 points for no symptoms and 100 points for vomiting, and listen to 3 times of before acupuncture stimulation and before/after VR intervention.
The subjective symptom of motion sickness (SSMS) is used to evaluate motion sickness. SSMS consists of 7 items of dizziness, headaches, warmth, sweating, drowsiness, increasing salivation, and nausea in motion sickness. The degree of each symptom is rated on a scale of 4 and 6, and the minimum score is 0 and the maximum score is 49. This SSMS is listened to every 3 minutes for 15 minutes corresponding to VR intervention, and the transition of symptoms over time is confirmed.
介入/Interventional
クロスオーバー試験/Cross-over
ランダム化/Randomized
個別/Individual
介入実施者・測定者がブランド化されている単盲検/Single blind -investigator(s) and assessor(s) are blinded
プラセボ・シャム対照/Placebo
3
治療・ケア/Treatment
手技/Maneuver |
日本語
対照群(Sham鍼群):対象者は座位で電極装着およびVR装着準備を含めた安静20分のち、VRヘッドセットを装着し、安静時測定5分、鍼刺激20分、VR負荷15分の計40分間の実験を行う。VR負荷は、直径75 cmの円筒形を仮想空間とする。円筒形の内部は白6.2 cm、黒3.8 cmのストライプが交互に配置しており、その円筒形を60 °/secの速さで時計周りに15分間回転させ、動揺病を誘発させる。この際、自律神経症状を訴え、耐えられない場合には、ヘッドセットを外すよう指示する。Sham鍼群は、長さ40 mm、太さ0.80 mmのステンレス製特注鍼(大宝医科工業株式会社、広島、日本)に自作の鍼管を装着したSham鍼を消毒したうえで使用する。鍼刺激部位は、腓骨頭の直下と脛骨粗面下端との中間で前脛骨筋に位置する両側の足三里穴(ST36)に行う。
英語
Control group (sham acupuncture group): After 20 minutes of rest, including placement of the electrodes and the VR head set, the subjects are asked to sit on the chair for a total of 40 min: 5 min baseline period, 20 min acupuncture stimulation, and 15 min VR intervention. The VR intervention is created based on previous reports, and a cylindrical shape with a diameter of 75 cm become a virtual space. A cylindrical shape have alternating white 6.2 cm and black 3.8 cm vertical stripes inside, that is rotated clockwise at a speed of 60 degree per second for 15 minutes to induce optokinetic motion sickness. At this time, the subjects complain of autonomic nervous symptoms and are instructed to remove the VR head set if they could not tolerate it. In sham acupuncture group, we use custom-made (in-house) sham acupuncture needles with disinfected stainless acupuncture needles (0.80 mm diameter and 40 mm length; TAIHO Medical Products Co., Ltd., Hiroshima, Japan) inserted into a custom-made guide tube. The needling sites are performed on ST36 bilaterally located in the tibialis anterior muscle between the head of fibula and the lower end of the tibial tuberosity.
日本語
置鍼群:対象者は座位で電極装着およびVR装着準備を含めた安静20分のち、VRヘッドセットを装着し、安静時測定5分、鍼刺激20分、VR負荷15分の計40分間の実験を行う。VR負荷は、直径75 cmの円筒形を仮想空間とする。円筒形の内部は白6.2 cm、黒3.8 cmのストライプが交互に配置しており、その円筒形を60 °/secの速さで時計周りに15分間回転させ、動揺病を誘発させる。この際、自律神経症状を訴え、耐えられない場合には、ヘッドセットを外すよう指示する。置鍼群は、長さ40mm、太さ0.20mmのディスポーザブルステンレス鍼(セイリン株式会社、静岡、日本)を用いて体表面から直刺で15~20 mm刺入し、置鍼術(鍼を身体に刺入し、しばらくの間とどめておく方法)をVR負荷前の20分間行う。鍼刺激部位は、腓骨頭の直下と脛骨粗面下端との中間で前脛骨筋に位置する両側の足三里穴(ST36)に行う。
英語
Manual acupuncture group: After 20 minutes of rest, including placement of the electrodes and the VR head set, the subjects are asked to sit on the chair for a total of 40 min: 5 min baseline period, 20 min acupuncture stimulation, and 15 min VR intervention. The VR intervention is created based on previous reports, and a cylindrical shape with a diameter of 75 cm become a virtual space. A cylindrical shape have alternating white 6.2 cm and black 3.8 cm vertical stripes inside, that is rotated clockwise at a speed of 60 degree per second for 15 minutes to induce optokinetic motion sickness. At this time, the subjects complain of autonomic nervous symptoms and are instructed to remove the VR head set if they could not tolerate it. In manual acupuncture group, we use a sterile stainless acupuncture needle (diameter, 0.20 mm; length, 40 mm; SEIRIN Co., Shizuoka, Japan) and is inserted perpendicularly to a depth of 15~20 mm under the skin, and the manual acupuncture (insert a needle into the body and remain it for a while) is performed for 20 minutes in before VR intervention. The needling sites are performed on ST36 bilaterally located in the tibialis anterior muscle between the head of fibula and the lower end of the tibial tuberosity.
日本語
鍼通電群:対象者は座位で電極装着およびVR装着準備を含めた安静20分のち、VRヘッドセットを装着し、安静時測定5分、鍼刺激20分、VR負荷15分の計40分間の実験を行う。VR負荷は、直径75 cmの円筒形を仮想空間とする。円筒形の内部は白6.2 cm、黒3.8 cmのストライプが交互に配置しており、その円筒形を60 °/secの速さで時計周りに15分間回転させ、動揺病を誘発させる。この際、自律神経症状を訴え、耐えられない場合には、ヘッドセットを外すよう指示する。鍼通電群は、置鍼群と同様のディスポーザブルステンレス鍼を用いて体表面から直刺で15~20 mm刺入し、全医療器社製のOhm Pulser LFP2000eを用いて10Hzによる鍼通電をVR負荷前の20分間行う。鍼刺激部位は、腓骨頭の直下と脛骨粗面下端との中間で前脛骨筋に位置する両側の足三里穴(ST36)に行う。
英語
Electroacupuncture group: After 20 minutes of rest, including placement of the electrodes and the VR head set, the subjects are asked to sit on the chair for a total of 40 min: 5 min baseline period, 20 min acupuncture stimulation, and 15 min VR intervention. The VR intervention is created based on previous reports, and a cylindrical shape with a diameter of 75 cm become a virtual space. A cylindrical shape have alternating white 6.2 cm and black 3.8 cm vertical stripes inside, that is rotated clockwise at a speed of 60 degree per second for 15 minutes to induce optokinetic motion sickness. At this time, the subjects complain of autonomic nervous symptoms and are instructed to remove the VR head set if they could not tolerate it. In electroacupuncture group, we use a sterile stainless acupuncture needle similar to the manual acupuncture group and is inserted perpendicularly to a depth of 15~20 mm under the skin, and Ohm Pulser LFP-2000e (Zen Iryoki Co., Tokyo, Japan) is used to electroacupuncture at 10 Hz for 20 minutes in before VR intervention. The needling sites are performed on ST36 bilaterally located in the tibialis anterior muscle between the head of fibula and the lower end of the tibial tuberosity.
日本語
英語
日本語
英語
日本語
英語
日本語
英語
日本語
英語
日本語
英語
日本語
英語
18 | 歳/years-old | 以上/<= |
30 | 歳/years-old | 未満/> |
男/Male
日本語
参加者の適格基準は18歳から30歳までの健常男性
英語
The eligibility criteria for subjects are healthy male volunteers between the ages of 18 and 30.
日本語
除外基準は、①基礎疾患により通院および投薬を受けている、②睡眠障害により体調が優れない、③消化器疾患、内耳疾患、中枢神経疾患の既往歴がある者とする。
英語
The exclusion criteria are: (1) those who were to the hospital and on medication due to underlying medical conditions, (2) those who were unwell due to sleep disorders, (3) those with a history of gastrointestinal disorders and inner ear disorders, central nervous disorders.
28
日本語
名 | 賢治 |
ミドルネーム | |
姓 | 今井 |
英語
名 | Kenji |
ミドルネーム | |
姓 | Imai |
日本語
帝京平成大学
英語
Teikyo Heisei University
日本語
健康科学研究科
英語
Graduate School of Health Sciences
170-8445
日本語
東京都豊島区東池袋2-51-4
英語
2-51-4 Higashi-ikebukuro, Toshimaku, Tokyo
080-1527-1617
k.imai@thu.ac.jp
日本語
名 | 大侑 |
ミドルネーム | |
姓 | 篠原 |
英語
名 | Daiyu |
ミドルネーム | |
姓 | Shinohara |
日本語
帝京平成大学
英語
Teikyo Heisei University
日本語
健康科学研究科
英語
Graduate School of Health Sciences
170-8445
日本語
東京都豊島区東池袋2-51-4
英語
2-51-4 Higashi-ikebukuro, Toshimaku, Tokyo
080-5521-6516
d.shinohara1@gmail.com
日本語
その他
英語
Teikyo Heisei University
日本語
帝京平成大学
日本語
日本語
英語
日本語
その他
英語
Teikyo Heisei University
日本語
帝京平成大学
日本語
その他/Other
日本語
英語
日本語
英語
日本語
英語
日本語
帝京平成大学 倫理委員会
英語
Ethical commitie, Teikyo Heisei University
日本語
東京都豊島区東池袋2-51-4
英語
2-51-4 Higashi-ikebukuro, Toshimaku, Tokyo
03-5843-3111
rec@thu.ac.jp
いいえ/NO
日本語
英語
日本語
英語
2022 | 年 | 07 | 月 | 27 | 日 |
未公表/Unpublished
日本語
英語
日本語
英語
日本語
英語
日本語
英語
日本語
英語
日本語
英語
日本語
英語
日本語
英語
参加者募集終了‐試験継続中/No longer recruiting
2022 | 年 | 04 | 月 | 15 | 日 |
2022 | 年 | 07 | 月 | 25 | 日 |
2022 | 年 | 07 | 月 | 29 | 日 |
2022 | 年 | 10 | 月 | 01 | 日 |
日本語
英語
2022 | 年 | 07 | 月 | 26 | 日 |
2022 | 年 | 09 | 月 | 10 | 日 |
日本語
https://center6.umin.ac.jp/cgi-open-bin/ctr/ctr_view.cgi?recptno=R000055237
英語
https://center6.umin.ac.jp/cgi-open-bin/ctr_e/ctr_view.cgi?recptno=R000055237
研究計画書 | |
---|---|
登録日時 | ファイル名 |
研究症例データ仕様書 | |
---|---|
登録日時 | ファイル名 |
研究症例データ | |
---|---|
登録日時 | ファイル名 |